Automated determination of serum glutamic oxaloacetic transaminase.

نویسندگان

  • S Morgenstern
  • M Oklander
  • J Auerbach
  • J Kaufman
  • B Klein
چکیده

A simplified and precise automated method is described for the colorimetric determination of serum glutamic oxaloacetic transaminase. The enzymically generated oxaloacetic acid is dialyzed, coupled with Fast Ponceau L, a diazonium salt, to form a colored solution whose absorbance is measured at 455 m . Dialysis eliminates the need for a serum control determination, thereby halving the analysis time, which is usually 1 hr. per 40 specimens. Comparison of values obtained using this procedure with and without dialysis shows excellent agreement. Comparison with the spectrophotometric procedure shows good correlation. The results of sample interaction experiments are also presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of two current colorimetric procedures for determination of serum glutamic oxaloacetic transaminase.

A comparison of two colorimetric procedures for the determination of serum glutamic oxaloacetic acid (SCOT) showed that both the dinitrophenylhydrazine and diazonium salt colorimetric assay procedures have good precision and reproducibility acceptable to most clinical laboratories. Babson’s diazonium salt procedure (3) definitely shows greater precision in the important borderline range of valu...

متن کامل

Serum glutamic oxaloacetic transaminase in dissecting aneurysm of the thoracic aorta.

FOR obvious reasons, separation of the entities of myocardial infarction and dissecting aneurysm of the thoracic aorta has often presented a difficult and perplexing problem in clinical medicine. With the advent of serum glutamic oxaloacetic transaminase (SGOT) determination as a diagnostic measure in the diagnosis of myocardial infarction, it has been suggested' that this procedure may be of h...

متن کامل

Artifactual depression of serum glutamic oxaloacetic transaminase by metronidazole.

Eighteen patients developed abnormally low serum glutamic oxaloacetic transaminase values during metronidazole therapy. Metronidazole absorbs at 340 nm, simulating reduced nicotinamide adenine dinucleotide, which is the final colorimetric product of the serum glutamic oxaloacetic transaminase assay.

متن کامل

Serum activity patterns of glutamic oxaloacetic transaminase, glutamic pyruvic transaminase and lactic dehydrogenase following graded myocardial infarction in dogs.

Following experimental myocardial infarction in the dog elevations of serum levels of glutamie-oxaloacetic transaminase (SGO-T), glutamic-pyruvic transaminase (SGP-T) and lactic dehydrogenase (SLID) were consistently noted in decreasing order. Evidence is presented that leakage into the serum from the damaged myocardium plays an important role in these elevations. This concept is supported by a...

متن کامل

Free Radical Scavenging Activity of Calotropis gigantea on Streptozotocin-Induced Diabetic Rats

Swarnabhasma, an Ayurvedic preparation containing Calotropis gigantea R. Br. (Asclepiadaceae) is extensively used by Ayurvedic physicians for treatment of diabetes mellitus, bronchial asthma, rheumatoid arthritis and nervous disorders. In the present study, we report the effect of chloroform extracts of Calotropis gigantea leaf and flower on free radical scavenging activity, and lipid profile i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 1966