Myocardial first-pass perfusion imaging with hybrid-EPI: frequency-offsets and potential artefacts
نویسندگان
چکیده
BACKGROUND First-pass myocardial perfusion is often imaged with a tailored hybrid centric interleaved echo-planar-imaging sequence, providing rapid image acquisition with good contrast enhancement. The centric interleaved phase-encode order minimises the effective time-of-echo but it is sensitive to frequency-offsets. This short article aims to show possible artefacts that might originate with this sequence, in the context of first-pass perfusion imaging, when frequency-offsets are present. Non-uniform magnitude modulation effects were also analysed. METHODS Numerical and phantom simulations were used to illustrate the effects of frequency-offsets and non-uniform magnitude modulation with this sequence in a typical perfusion protocol. In vivo data was post-processed to analyse the h-EPI's sensitivity to the frequency-offsets. RESULTS The centric phase-order was shown to be highly sensitive to frequency-offsets due to its symmetrical phase slope. Resulting artefacts include blurring, and splitting of the image into two identical copies along the phase-encode direction. It was also shown that frequency-offsets can introduce signal loss and ghosting of the right ventricle signal into the myocardium. The in vivo results were confirmed by numerical and phantom simulations. Magnitude modulation effects were found to be small. CONCLUSIONS Imaging first-pass myocardial perfusion with an hybrid centric echo-planar-imaging sequence can be corrupted with ghosting and splitting of the image due to frequency-offsets.
منابع مشابه
Method for correcting respiratory artefacts in parallel-accelerated first-pass myocardial perfusion imaging
Background Myocardial first-pass perfusion (MPI) requires singleshot imaging of multiple slices per cycle. Breath-holding supports advanced high-resolution MPI methods, but tolerance to respiratory motion is desirable. Respiratory misregistration can induce aliasing artefacts by inaccurate coil sensitivity calibration, particularly at higher acceleration factors and during stress hyperpnea. Coi...
متن کاملMyocardial first pass perfusion: steady-state free precession versus spoiled gradient echo and segmented echo planar imaging.
The imaging sequences used in first pass (FP) perfusion to date have important limitations in contrast-to-noise ratio (CNR), temporal and spatial resolution, and myocardial coverage. As a result, controversy exists about optimal imaging strategies for FP myocardial perfusion. Since imaging performance varies from subject to subject, it is difficult to form conclusions without direct comparison ...
متن کاملNon-rigid registration and KLT filter to improve SNR and CNR in GRE-EPI myocardial perfusion imaging.
The purpose of the study was to evaluate the effect of motion compensation by non-rigid registration combined with the Karhunen-Loeve Transform (KLT) filter on the signal to noise (SNR) and contrast-to-noise ratio (CNR) of hybrid gradient-echo echoplanar (GRE-EPI) first-pass myocardial perfusion imaging. Twenty one consecutive first-pass adenosine stress perfusion MR data sets interpreted posit...
متن کاملHigh reproducibility of adenosine stress cardiac MR myocardial perfusion imaging in patients with non-ischaemic dilated cardiomyopathy
OBJECTIVE To evaluate the reproducibility of first-pass contrast-enhanced cardiac MR (CMR) myocardial perfusion imaging in patients with non-ischaemic dilated cardiomyopathy (NIDCM). DESIGN Prospective observational study. SETTING Single centre, tertiary care hospital. PARTICIPANTS 6 outpatient participants with NIDCM. OUTCOME Reproducibility of semiquantitative myocardial perfusion ana...
متن کاملComparison of dipyridamole – induced electrocardiographic changes and myocardial perfusion imaging in diagnosis of coronary artery disease [Persian]
Introduction: This study evaluated the diagnostic value of the dipyridamole induced electrocardiuogram (ECG) cahnges, comparing with myocardial perfusion imaging. Materials and Methods: 222 patinets were studied with dipyridamole infusion (based on ECG criteria) as well as Dipyridamole-myocardial perfusion imaging (MPI). Results: Abnormal dipyridamole test and abnormal MPI were noted in 1...
متن کامل