Influence of resting periods on polyethylene wear in a knee simulator study.

نویسندگان

  • J Philippe Kretzer
  • Eike Jakubowitz
  • Kerstin Hofmann
  • Christian Heisel
  • Eva Lietz
چکیده

BACKGROUND Knee wear simulator studies are performed to evaluate the wear behavior of implants. These wear studies simulate in vivo situations as closely as possible. Simulation of the human gait cycle is often carried out continuously according to international standards. However, implants are not loaded continuously in vivo, so it might be advisable to implement resting periods in which no motion occurs. MATERIAL/METHODS In the present study the influence of resting periods on the wear behavior of a commercial implant was analyzed using a force-controlled AMTI knee simulator. RESULTS The wear rates were 2.27+/-0.23 mg/10(6) cycles for a simulation with resting periods and 2.85+/-0.27 mg/10(6) cycles for a reference simulation without resting periods. There was no significant difference (p=0.22) in wear behavior between these two tests. CONCLUSIONS The present study shows that continuous simulation without the implementation of resting periods is a valid approach for assessing the wear of knee implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of joint laxity on polyethylene wear in total knee replacement.

Experimental simulator studies are frequently performed to evaluate wear behavior in total knee replacement. It is vital that the simulation conditions match the physiological situation as closely as possible. To date, few experimental wear studies have examined the effects of joint laxity on wear and joint kinematics and the absence of the anterior cruciate ligament has not been sufficiently t...

متن کامل

Albumin Protein Cleavage Affects the Wear and Friction of Ultra-High Molecular Weight Polyethylene

It is well established that the total protein concentration and albumin-to-globulin ratio influence the wear of ultra-high molecular polyethylene (UHMWPE, "polyethylene") in joint prostheses. A factor on wear not yet studied, but of possible clinical relevance, is protein cleavage. Such cleavage is expected in the presence of an inflammatory response and as a result of wear processes at the art...

متن کامل

Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners

The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display-using a 3D optical scanner-wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee c...

متن کامل

The influence of femoral condylar lift-off on the wear of artificial knee joints.

In vivo fluoroscopic studies of patients with total knee replacements (TKRs) have shown lift-off of the femoral condyles from the tibial insert. This study investigated the influence of femoral condylar lift-off on the ultra-high molecular weight polyethylene (UHMWPE) wear of fixed bearing (FB) and rotating platform mobile bearing (RP MB) total knee replacements, using a physiological knee join...

متن کامل

The influence of simulator input conditions on the wear of total knee replacements: An experimental and computational study

Advancements in knee replacement design, material and sterilisation processes have provided improved clinical results. However, surface wear of the polyethylene leading to osteolysis is still considered the longer-term risk factor. Experimental wear simulation is an established method for evaluating the wear performance of total joint replacements. The aim of this study was to investigate the i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical science monitor : international medical journal of experimental and clinical research

دوره 15 11  شماره 

صفحات  -

تاریخ انتشار 2009