Identification of infants with significant refractive error and strabismus in a population screening program using noncycloplegic videorefraction and orthoptic examination.
نویسندگان
چکیده
PURPOSE The second Cambridge Infant Vision Screening Program examined whether screening for accommodative errors by using videorefraction without cycloplegia could effectively serve as a first stage of screening for refractive errors, measured by standard cycloplegic retinoscopy. The screening also included an orthoptic examination for detection of strabismus. METHODS All infants born in the Cambridge (UK) Health District, over a 2-year period, were invited for screening. Of those 5142 (76%) with mean age 8.1 +/- 0.8 months (SD) attended and received noncycloplegic videorefraction and an orthoptic examination. All those with a focusing error or orthoptic problem, as well as a randomly selected sample of visually normal control subjects, were invited to follow-up a month later for cycloplegic retinoscopy, repeat noncycloplegic videorefraction and orthoptic examination. RESULTS Of the 5142 screened, 514 had a focusing error or orthoptic problem (positives). Four hundred thirty-nine of these and 284 visually normal control subjects (negatives) attended follow-up. A refractive or orthoptic condition was confirmed in 59.0% of the positive cases, whereas infants in 96.8% of the negative cases were confirmed normal. Adjusting for the proportions of the population represented by those infants seen at follow-up, sensitivity for the screening procedure was calculated at 0.67 and specificity at 0.96. Detailed results are presented in terms of the different conditions detected at screening (far, near, and anisometropic focus and orthoptic error), distribution of greatest axes at screening, and a comparison of initial videorefraction with repeat videorefraction and cycloplegic retinoscopy. CONCLUSIONS A noncycloplegic screening procedure, simpler to perform than cycloplegic screening, succeeded in detecting a large proportion of infants with significant ametropia, particularly those with significant hyperopia, which is considered to be a strabismogenic and amblyogenic risk factor.
منابع مشابه
Visual acuity screening versus noncycloplegic autorefraction screening for astigmatism in Native American preschool children.
INTRODUCTION Visual acuity screening (VAS) is less reliable in preschoolers than in school-aged children as a means of detecting significant refractive error. We wished to compare the effectiveness of VAS with the effectiveness of an objective method, noncycloplegic autorefraction screening (NCARS), in detecting the presence of significant astigmatism warranting spectacle correction. METHODS ...
متن کاملDoes assessing eye alignment along with refractive error or visual acuity increase sensitivity for detection of strabismus in preschool vision screening?
PURPOSE Preschool vision screenings often include refractive error or visual acuity (VA) testing to detect amblyopia, as well as alignment testing to detect strabismus. The purpose of this study was to determine the effect of combining screening for eye alignment with screening for refractive error or reduced VA on sensitivity for detection of strabismus, with specificity set at 90% and 94%. ...
متن کاملManifest strabismus following pseudostrabismus diagnosis.
INTRODUCTION Pseudostrabismus is a common diagnosis in a busy pediatric ophthalmology practice. This purpose of this study was to determine the prevalence of true strabismus in patients previously diagnosed with pseudostrabismus, to determine risk factors, and to examine the sensory outcome. METHODS This is a retrospective review of patients diagnosed with pseudo-strabismus and with at least ...
متن کاملAssessment of Grating Acuity in Infants and Toddlers Using an Electronic Acuity Card: The Dobson Card.
PURPOSE To determine if testing binocular visual acuity in infants and toddlers using the Acuity Card Procedure (ACP) with electronic grating stimuli yields clinically useful data. METHODS Participants were infants and toddlers ages 5 to 36.7 months referred by pediatricians due to failed automated vision screening. The ACP was used to test binocular grating acuity. Stimuli were presented on ...
متن کاملNormal emmetropization in infants with spectacle correction for hyperopia.
PURPOSE The development of emmetropic refraction is known to be under visual control. Does partial spectacle correction of infants' refractive errors, which has been shown to have beneficial effects in reducing strabismus and amblyopia, impede emmetropization? The purpose of the present study was to perform the first longitudinal controlled trial to investigate this question in human subjects. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 44 2 شماره
صفحات -
تاریخ انتشار 2003