Personalization of Device Therapy - Prime Time for Peak Inspiratory Flow Rate.
نویسندگان
چکیده
Abbreviations: chronic obstructive pulmonary disease, COPD; National Health and Nutrition Examination Survey, NHANES; Global initiative for chronic Obstructive Pulmonary Disease, GOLD; metered dose inhalers, MDIs; dry powder inhalers, DPIs; tumor necrosis factor α, TNFα; forced vital capacity, FVC; forced expiratory volume in 1 second, FEV1 Citation: Loh CH, Ohar JA. Editorial: Personalization of device therapy – prime time for peak inspiratory flow. Chronic Obstr Pulm Dis. 2017;4(3):172-176. doi: https://doi.org/10.15326/jcopdf.4.3.2017.0155 Editorial
منابع مشابه
Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery
Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...
متن کاملReliability of an Electronic Inspiratory Loading Device for Assessing Pulmonary Function in Post-Stroke Patients
BACKGROUND The purpose of this study was to examine the inter- and intra-rater reliability of an electronic inspiratory loading device for the assessment of pulmonary functions: maximum inspiratory pressure, peak inspiratory flow, and vital capacity. MATERIAL/METHODS Subjects were 50 patient volunteers in a rehabilitation hospital who had experienced their first episode of unilateral stroke w...
متن کاملSystems Physiology: Cardiopulmonary THE EFFECTS OF RESPIRATORY MUSCLE TRAINING ON VO2 MAX, THE VENTILATORY THRESHOLD AND PULMONARY FUNCTION
THE EFFECTS OF RESPIRATORY MUSCLE TRAINING ON VO2 MAX, THE VENTILATORY THRESHOLD AND PULMONARY FUNCTION. William E. Amonette, Terry L. Dupler. JEPonline. 2002;5(2):29-35. This study evaluated the effect of inspiratory and expiratory muscle training on pulmonary function and maximal exercise performance in competitive triathletes and marathon runners. The participants in this study (N=12) had a ...
متن کاملPeak inspiratory flow through Turbuhaler in acute asthma.
Efficient use of dry powder inhalers, such as Turbuhaler, is dependent on the generation of adequate inspiratory flow. It is not clear whether patients with acute asthma are able to generate adequate flow. Peak inspiratory flow (PIF) was measured through an empty Turbuhaler, and without this device, in 99 adults presenting to hospital with acute exacerbations of asthma. Where possible, patients...
متن کاملPeak inspiratory flow rate and slope of the inhalation profiles in dry powder inhalers.
Aerosol delivery depends on device design and inhalation technique. In vitro device evaluations have shown that the emitted dose and fine particle mass of dry powder inhalers (DPIs) increase at high peak inspiratory flow rates (PIFR). Since the PIFR is mostly achieved after the release of the powder, slope of the pressure profile is also described as an important determinant. The aim of the pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chronic obstructive pulmonary diseases
دوره 4 3 شماره
صفحات -
تاریخ انتشار 2017