Deciphering the Contribution of Biofilm to the Pathogenesis of Peritoneal Dialysis Infections: Characterization and Microbial Behaviour on Dialysis Fluids

نویسندگان

  • Joana Sampaio
  • Diana Machado
  • Ana Marta Gomes
  • Idalina Machado
  • Cledir Santos
  • Nelson Lima
  • Maria João Carvalho
  • António Cabrita
  • Anabela Rodrigues
  • Margarida Martins
چکیده

Infections are major complications in peritoneal dialysis (PD) with a multifactorial etiology that comprises patient, microbial and dialytic factors. This study aimed at investigating the contribution of microbial biofilms on PD catheters to recalcitrant infections and their interplay with PD related-factors. A prospective observational study was performed on 47 patients attending Centro Hospitalar of Porto and Vila Nova de Gaia/Espinho to whom the catheter was removed due to infectious (n = 16) and non-infectious causes (n = 31). Microbial density on the catheter was assessed by culture methods and the isolated microorganisms identified by matrix-assisted laser desorption/ionization time-of-flight intact cell mass spectrometry. The effect of conventional and three biocompatible PD solutions on 16 Coagulase Negative Staphylococci (CNS) and 10 Pseudomonas aeruginosa strains planktonic growth and biofilm formation was evaluated. Cultures were positive in 87.5% of the catheters removed due infectious and 90.3% removed due to non-infectious causes. However, microbial yields were higher on the cuffs of catheters removed due to infection vs. non-infection. Staphylococci (CNS and Staphylococcus aureus) and P. aeruginosa were the predominant species: 32% and 20% in the infection and 43.3% and 22.7% in the non-infection group, respectively. In general, PD solutions had a detrimental effect on planktonic CNS and P. aeruginosa strains growth. All strains formed biofilms in the presence of PD solutions. The solutions had a more detrimental effect on P. aeruginosa than CNS strains. No major differences were observed between conventional and biocompatible solutions, although in icodextrin solution biofilm biomass was lower than in bicarbonate/lactate solution. Overall, we show that microbial biofilm is universal in PD catheters with the subclinical menace of Staphylococci and P. aeruginosa. Cuffs colonization may significantly contribute to infection. PD solutions differentially impact microbial species. This knowledge is important for the development of infection diagnosis, treatment and preventive strategies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cytotoxic Glucose Degradation Products in Fluids for Peritoneal Dialysis

During the standard heat sterilization process of the lactate–buffered peritoneal dialysis solutions, glucose (an osmotic active substance) degrades to form compounds called glucose degradation products which are cytotoxic and affect the survival of the peritoneal membrane. This case presentation is based on an observation of 224 aseptic peritonitis cases of unknown etiology. For the purpose of...

متن کامل

Cytotoxic Glucose Degradation Products in Fluids for Peritoneal Dialysis

During the standard heat sterilization process of the lactate–buffered peritoneal dialysis solutions, glucose (an osmotic active substance) degrades to form compounds called glucose degradation products which are cytotoxic and affect the survival of the peritoneal membrane. This case presentation is based on an observation of 224 aseptic peritonitis cases of unknown etiology. For the purpose of...

متن کامل

Correlation between Ultrafiltration Coefficient and Effective Lymphatic Absorption Rate in Continuous Ambulatory Peritoneal Dialysis Patients: A Possible Paradigm Shift

Background: The relative contribution of transcapillary water movement and lymphatic reabsorption in peritoneal dialysis (PD) is a critical issue, particularly in patients with ultrafiltration failure (UFF). Based on routine results obtained from the PD Adequest 2.0 software, the present study aimed to re-evaluate the separate effects of transcapillary water movement and lymphatic reabsorption ...

متن کامل

گزارش سه مورد CVVHD) Continous Venovenous Hemodialysis)

Some of ICU patients with Acute Renal Failure (ARF) require dialysis. Conventional or intermittent hemodialysis (HD) may cause hypotension and insufficient loss of fluids and toxins from blood. Peritoneal dialysis also my cause peritonitis and has lower efficiency than HD. We did continuous Venovenous Hemodialysis (CVVHD) for three ICU patients with ARF in Saint-Zahra Medical Center for the fir...

متن کامل

A Comparative Study on Using Coiled Versus Straight Swan-Neck Tenckhoff Catheters in Patients Undergoing Peritoneal Dialysis

The key to successful long-term peritoneal dialysis (PD) is permanent and safe access to peritoneal cavity. The two most commonly used Tenckoff catheters for PD are the straight and coiled catheters. The present study was undertaken to assess the catheter survival, catheter associated infections, and all cause mortality and to compare the straight with coiled catheters in PD. During April 1997-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016