Measurement of glycated hemoglobin A1c from dried blood by turbidimetric immunoassay.

نویسندگان

  • Ramakrishnan Lakshmy
  • Ruby Gupta
چکیده

BACKGROUND Glycated hemoglobin A1c (A1C) is an important marker in the diagnosis and treatment of diabetes. Dried blood measurement of A1C is useful in large scale epidemiological evaluation of A1C, especially to assess the impact of intervention programs. The possibility of using dried blood for measurement of A1C by the immunoturbidimetric method was explored in the present study. METHOD Blood was collected from 30 patients, and blood spots were prepared and dried. The dried blood spot samples were kept for different lengths of time at 4 degrees C to assess stability. Glycated hemoglobin was measured in whole blood and dried blood on the day of collection as well as on days 10 and 15 by immunoturbidimetric method. RESULTS The A1C values of 30 samples analyzed for comparison between whole blood estimation and dried blood ranged from 4.6% to 9.9%. The mean A1C on the day of sample collection was 6.01% +/- 1.58% in fresh whole blood samples and 5.94% +/- 1.58 % in dried blood spots. A linear and highly correlated relationship was observed between dried blood A1C values and those in whole blood (r = 0.986 and intraclass correlation value = 0.993). Glycated hemoglobin values on day 10 and day 15 were comparable with the values on day 1 with a shift in mean of just 1% on day 10 and 3.04% on day 15. CONCLUSION In conclusion, dried blood can be used for measurement of A1C by immunoturbidimetric method, and further stability of A1C measurement from dried blood for up to 15 days at 4 degrees C makes it an ideal matrix for transportation in developing countries like India.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of filter paper method for measuring glycated hemoglobin.

BACKGROUND AND OBJECTIVES Glycated hemoglobin (HbA1c) provides an accurate and reliable method to assess the glycemic control in patients with Diabetes. Its measurement is limited by the inconvenience of sample collection that requires venipuncture, sample handling and storage factors. The aim of this study was to assess the feasibility of using a dried capillary blood spot on a filter paper to...

متن کامل

The use of dried blood spot sampling for the measurement of HbA1c: a cross-sectional study

BACKGROUND The use of dried blood spot (DBS) sampling is an alternative to traditional venous blood collection, and particularly useful for people living in rural and remote areas, and for those who are infirm, house-bound or time-poor. The objective of this study was to assess whether the measurement of glycated haemoglobin A1c (HbA1c) in DBS samples provided comparative and acceptably precise...

متن کامل

Glycated haemoglobin A1c measurement in stored whole blood sample is reliable for clinical use.

Glycated haemoglobin A1c (HbA1c) gives an integrated plasma glycaemia for the previous 2-3 months and its measurement is central in the management of diabetic patients. However in many developing countries because kits/regents or expertise for HbA1c measurement are not always available and the test must be conducted on fresh whole blood samples, HbA1c tests are not routinely performed Thus, thi...

متن کامل

Translating the A1C Assay

In the clinical management of diabetes, the A1C assay has become indispensable. Used worldwide to monitor chronic glycemia, the assay is an essential tool to determine whether a patient has achieved the core goal of therapy for diabetes: a marked and sustained reduction in plasma glucose to achieve as close to a normal level as can be safely attained. With the publication of the A1c-Derived Ave...

متن کامل

Pitfalls of glycated hemoglobin in the glycemic assessment of diabetes patients with hemoglobin louisville: role of serum fructosamine.

Fasting blood glucose measurements were made using the hexokinase method in a Cobas 6000 (Roche Diagnostics, Rotkreuz, Switzerland). Determinations of HbA1c were performed on ethylenediaminetetraacetic acid–anticoagulated blood sample by two methods: high-performance liquid chromatography (HPLC) (HA-8160 in diabetic mode, A. Menarini Diagnostics, Florence, Italy), which detected no abnormal hem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 3 5  شماره 

صفحات  -

تاریخ انتشار 2009