Graded balloon dilatation as a prerequisite to Amplatzer device closure of perforated interatrial septal aneurysm.
نویسندگان
چکیده
This case report describes a modification in the technique of atrial septal device closure in a patient with atrial septal defect (ASD) with associated atrial septum aneurysm and significant left-to-right shunt through multiple perforations. Graded balloon dilatation of the aneurysm was performed in this patient, as a preamble to successful deployment of a single large Amplatzer atrial septal occluder, closing the ASD completely and entrapping the aneurysm as a whole.
منابع مشابه
Balloon assisted technique for closure of large atrial septal defects
Amplatzer device closure of large atrial septal defects is challenging. A large device tends to malalign with the plane of the interatrial septum or prolapses through the defect. We describe a balloon assisted technique which has been successfully used in over 300 cases without a single technical failure.
متن کاملTranscatheter closure of patent foramen ovale using the Amplatzer septal occluder to prevent recurrence of neurological decompression illness in divers.
OBJECTIVE Large flap valve patent foramens may cause paradoxical thromboembolism and neurological decompression illness in divers. The ability of a self expanding Nitinol wire mesh device (Amplatzer septal occluder) to produce complete closure of the patent foramen ovale was assessed. PATIENTS Seven adults, aged 18-60 years, who had experienced neurological decompression illness related to di...
متن کاملCoronary anomaly preventing transcatheter closure of an atrial septal defect.
A 4-year-old asymptomatic girl presented for elective transcatheter closure of her ostium secundum atrial septal defect (ASD). Her examination revealed a fixed split second heart sound with a 2/6 systolic ejection murmur at the left upper sternal border and a right ventricular lift. Transthoracic echocardiogram demonstrated a 15-mm secundum ASD with a mildly dilated right ventricle. The left co...
متن کاملTranscatheter closure of secundum atrial septal defects and fenestrated Fontan using the Amplatzer septal occluder. Initial prospective study.
OBJECTIVE To evaluate the safety and efficacy of transcatheter closure of secundum atrial septal defects and fenestrated Fontan with the Amplatzer septal occluder. METHODS Fifteen consecutive patients, with a significant interatrial communications, were considered for the procedure; four patients with defects that were too large or with deficient margins were excluded after initial transesoph...
متن کاملTranscatheter closure of atrial septal defects--is balloon sizing still necessary?
INTRODUCTION The device closure of atrial septal defects has evolved over the years. In the early days of transcatheter occlusion, balloon sizing was used to choose an appropriate sized device. We postulate that balloon sizing does not value-add to the procedure and is unnecessary. MATERIALS AND METHODS Patients who had balloon sizing, with (Group 1, n = 38) or without (Group 2, n = 21) atria...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Singapore medical journal
دوره 53 1 شماره
صفحات -
تاریخ انتشار 2012