Employment of 4-(1-imidazolyl)phenol as a luminol signal enhancer in a competitive-type chemiluminescence immunoassay and its comparison with the conventional antigen–horseradish peroxidase conjugate-based assay

نویسندگان

  • Yannis Dotsikas
  • Yannis L. Loukas
چکیده

This study describes the employment of a novel imidazole-substituted phenol [4-(1-imidazolyl)phenol] as a highly potent signal enhancer in a horseradish peroxidase (HRP)–luminol chemiluminescence (CL) immunoassay. This competitive-type immunoassay for the model antigen fentanyl is based on the use of fentanyl polyclonal antibody immobilized on white microtiter plates and a biotinylated bovine serum albumin (BSA)–fentanyl derivative as a tracer. The latter was detected by means of streptavidin labeled with HRP, resulting in the generation of a high-intensity and relatively stable chemiluminescent signal, immediately after the addition of the substrate solution (NOAS). The developed method fulfilled the requirements of accuracy (percentage recovery ranged from 93.8 to 107%) and precision (intraand inter-assay CVs were 2.5–5.2 and 4.5–11.9%, respectively). Its plasma detection limit (1.05 pg ml−1) was lower than those of previous immunoassays. The novel assay was compared in terms of sensitivity and concentration range with other common HRP substrate systems: luminol–p-iodophenol–H2O2 and TMB–H2O2. Finally, the described method was compared with an HRP–fentanyl conjugate-based assay, similar to commercially available kits (SKIT), employing the novel substrate solution for both assays and the differences observed were explained by applying previously described models. The detection limit was 4.82 pg ml−1 for SKIT, recovery values were 94.2–105% and intraand inter-assay CVs were 2.5–5.2 and 4.5–11.9%, respectively. In conclusion, the proposed assay could be utilized for a wide range of molecules and replace the existing enzyme-labeled antigen-based kits. © 2003 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved performance of antigen-HRP conjugate-based immunoassays after the addition of anti-HRP antibody and application of a liposomal chemiluminescence marker.

To overcome the sensitivity limit for small molecules (haptens) in immunoassays based on antigen-horseradish peroxidase (HRP) conjugates as labels, a novel approach was established that afforded very low detection limits. Biotinylated anti-HRP antibody was utilized in order to attach, via a streptavidin bridge, liposomaly entrapped HRP. Fentanyl, used as a model antigen, could be determined via...

متن کامل

Phenols as enhancers of the chemiluminescent horseradish peroxidase-luminol-hydrogen peroxide reaction: application in luminescence-monitored enzyme immunoassays.

Certain phenol derivatives, including p-iodophenol and p-phenylphenol, enhance light emission from the horseradish peroxidase-catalyzed oxidation of cyclic diacyl hydrazides such as luminol. The light emission decays slowly (glowing for several minutes) and its intensity may be greater than 1000-fold that of the unenhanced reaction. The enhanced system enables rapid, sensitive assay of peroxida...

متن کامل

Enhanced chemiluminescence labeled-antibody immunoassay (Amerlite-MAB) for free thyroxine: design, development, and technical validation.

We describe the development and validation of a one-step nonradioactive immunoassay for free thyroxine (Amerlite-MAB FT4) in serum or plasma, in the dedicated Amerlite enhanced luminescence assay system. A monoclonal antibody to thyroxine (T4), conjugated with horseradish peroxidase (HRP; EC 1.11.1.7), competes for binding with FT4 or with a conjugate of a protein and L-triiodothyronine immobil...

متن کامل

Chemiluminescence immunoassay for a nonionic surfactant using a compact disc-type microfluidic platform*

A simple and pump-free chemiluminescence immunoassay based on a compact disc (CD)-type microfluidic platform for the determination of alkylphenol polyethoxylates (APnEOs) is described. The method is based on a competitive immunoreaction of the antiAPnEOs antibody immobilized on the magnetic microbeads between APnEOs and horseradish peroxidase (HRP)-labeled APnEOs in the sample solution. The lum...

متن کامل

Hydrogen peroxide assay by using enhanced chemiluminescence of the luminol-H202--horseradish peroxidase system: Comparative studies

p-Iodophenol, p-coumaric acid, phenol and aniline are enhancers of the luminol-H202-horseradish peroxidase chemiluminescence. These enhanced and unenhanced chemiluminescences were used to assay low concentrations of hydrogen peroxide. The curves of cherniluminescence intensity maxima against hydrogen peroxide concentration were fitted to third order polynomial regressions, which permit a very g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004