In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment

نویسندگان

  • Giancarlo Cordasco
  • Antonino Lo Giudice
  • Angela Militi
  • Riccardo Nucera
  • Giuseppe Triolo
  • Giovanni Matarese
چکیده

OBJECTIVE To investigate the resistance to sliding (RS) in self-ligating and conventional ligation bracket systems at 5 different second-order bracket angulations by using low-stiffness alignment wires in a 3-bracket experimental model and to verify the performance of the main RS components in both systems when these wires are used. METHODS Interactive self-ligating brackets with closed and open slides were used for the self-ligating (SL) and conventional ligation (CL) groups, respectively; elastomeric ligatures (1 mm inner diameter) were used in the latter system. The alignment wire used was 0.014 inch heat-activated NiTi (austenitic finish temperature set at 36℃ by the manufacturer). A custom-made testing machine was used to measure frictional resistance. Tests were repeated 5 times at every angulation simulated. All data were analyzed statistically. RESULTS The RS increased significantly with increasing angulation in both SL and CL groups (p < 0.0001). However, the RS values were significantly higher at every angulation (p < 0.0001) in the CL group. CONCLUSIONS Despite the relevance of the binding phenomenon, ligation forces predominantly affect the RS when low-stiffness alignment wires are used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Third-order torque and self-ligating orthodontic bracket-type effects on sliding friction.

OBJECTIVE To examine the influence of third-order torque on kinetic friction in sliding mechanics involving active and passive self-ligating brackets. MATERIALS AND METHODS Wire-slot frictional forces were quantified and compared across five sets of brackets and tubes within a simulated posterior dental segment with -15 degrees , -10 degrees , -5 degrees , 0 degrees , +5 degrees , +10 degrees...

متن کامل

Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.

AIM The aim of this study was to compare frictional resistance which was produced between conventional brackets (0.022 slot Otho-Organiser) and self ligating brackets (active Forestadent and passive Damon III) by using various arch wire combinations (0.016 Niti, 0.018 Niti, 0.017 x 0.025 SS and 0.019 x 0.025 SS). METHODS An experimental model which consisted of 5 aligned stainless steel 0.022...

متن کامل

Resistance to Sliding in Clear and Metallic Damon 3 and Conventional Edgewise Brackets: an In vitro Study

STATEMENT OF THE PROBLEM Frictional forces are considered as important counterforce to orthodontic tooth movement. It is claimed that self-ligating brackets reduce the frictional forces. PURPOSE The aim of this study was to compare the resistance to sliding in metallic and clear Damon brackets with the conventional brackets in a wet condition. MATERIALS AND METHOD The samples included 4 typ...

متن کامل

Evaluation of frictional forces during dental alignment: an experimental model with 3 nonleveled brackets.

INTRODUCTION The aim of this in-vitro study was to evaluate the frictional forces generated by various combinations of brackets and orthodontic wires by using an experimental model with 3 nonleveled brackets to gain a better understanding of the resistance to sliding during dental alignment and leveling. METHODS Two kinds of orthodontic brackets were tested: passive self-ligating brackets and...

متن کامل

A study of the frictional characteristics of four commercially available self-ligating bracket systems.

The objective of this investigation was to assess and compare the in vitro tribological behaviour of four commercially available self-ligating bracket systems. The frictional characteristics of the Damon3, Speed, In-Ovation R, and Time2 bracket systems were studied using a jig that mimics the three-dimensional movements that occur during sliding mechanics. Each bracket system was tested on the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2012