Objective: The new Ultra-TechneKowt Dry Ship Top Elute 99mTc generator (UTKt-DTE generator; Mallinckrodt Medical, Inc., St. Louis, MO) was devised to facilitate fractionated elution with an ergonomically designed elution shield. Fractionation is accomplished traditionally by visually observing the eluted volume through 2 layers of leaded glass windows located in a lighted elution shield and generator auxiliary shield. The goal of our study was to use elution time to determine the endpoint for obtaining the required volume of 99mTc-eluate from a UTK-DTE generator. Methods: After triplicate elution at several predetermined elution times, the initial weight of the evacuated collecting vial was subtracted from the total weight after elution to determine the elution volume. Results: A quadratic relationship was established between the eluate volume (v, mL) and elution time (t, s) (v 5 0.3594 1 0.1889 t – 0.0009 t2). This equation is suitable for use with the 10-mL elution vial. This formula may not be accurate for the first elution since the UTK-DTE generator is a dry-column generator when shipped. The following elution times were calculated for some commonly eluted volumes: 2 mL (9 s), 4 mL (22 s), 5 mL (28 s), 7 mL (45 s), and 10 mL (88 s). Conclusion: Our calculated elution time method can be used to predict the eluate volume from a UTK-DTE generator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of molybdenum breakthrough levels in molybdenum-99/technetium-99m generators: One year experience at NIMRA Jamshoro Pakistan

Background: Technetium-99m radioisotope is the backbone of any nuclear medicine institute. This radioisotope is acquired by the elution of Molybdenum-99/Technetium-99m generator which emits 141 keV gamma ray and having 6.04 hour half-life. Occasionally the contents of Molybdenum-99 may mix up with elute, which may affect image quality and patients may receive higher doses than recommended. This...

متن کامل

A New99m Tc Generator using Cerium (IV) Oxide as an Adsorbent for99 Mo

In this research, a new technetium-99m generator has been developed with addition of Cerium oxide to alumina column.  The adsorption behaviors of 99Mo in the form of molybdate and 99mTc in the form of pertechnetate on CeO2/Al2O3 was investigated and showed that the adsorption capacity of molybdate on this generator is higher than usual generator using Al2O3. Ceric ions were selected as an addit...

متن کامل

NUCLEAR PHARMACY Is Your Technetium Generator Eluate Sterile?

Objective: This study was performed to assess the sterility of multidose 99mTc generator eluate vials at the end of a working day. Methods: Expired 99mTc generator eluate vials were collected over a period of 10 wk and stored until the activity reached background. Four batches of 10 vials each were selected randomly and sent to an independent microbiology laboratory for sterility testing. Resul...

متن کامل

Dose from syringe procedures during technetium-99m radiopharmaceutical preparation.

UNLABELLED We examined the dose from 99mTc contained in syringes and shielded vials to assess in detail the dose burdens in a central pharmacy. METHODS Absorbed-dose rates at the end of the plunger of a shielded syringe, when 99mTc is contained either in the syringe or in a shielded vial from which the activity would be drawn, were measured with CaF2 dosimeters. The dose rates also were calcu...

متن کامل

NUCLEAR PHARMACY Dose from Syringe Procedures During Technetium-99m Radiopharmaceutical Preparation

We examined the dose from mTc contained in syringes and shielded vials to assess in detail the dose burdens in a central pharmacy. Methods: Absorbed-dose rates at the end of the plunger of a shielded syringe, when mTc is contained either in the syringe or in a shielded vial from which the activity would be drawn, were measured with CaF2 dosimeters. The dose rates also were calculated with a Mon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001