Ambulatory oximetry monitoring in patients with severe COPD: a preliminary study.

نویسندگان

  • J Pilling
  • M Cutaia
چکیده

BACKGROUND The benefits of long-term oxygen supplementation in COPD patients with hypoxemia are well established. The standard approach to prescribing oxygen uses a static assessment of oxygen requirements in a hospital or clinic setting. The assumption behind this approach is that patients will maintain a "therapeutic" hemoglobin oxygen saturation (SpO2) in the outpatient setting. We questioned the validity of this assumption, and hypothesized that many patients may demonstrate significant oxygen desaturation during normal activities of daily living. STUDY DESIGN, METHODS, AND MEASUREMENTS: We determined if oxygen supplementation maintained a therapeutic SpO2 level in patients with COPD (n = 27), using the technique of ambulatory oximetry monitoring (AOM). AOM consisted of using a portable oximeter to monitor SpO2, pulse rate, and patient activity while patients were engaged in normal activities of daily living over an extended time period (approximately 18 h). The portable oximeter collected and stored these data every 15 s over the monitored time period. Each AOM recording was manually scored for desaturation events and other key variables, including average SpO2 over the monitoring period, the average number of desaturation events per hour, and the percentage of monitored time deleted secondary to artifacts. SETTING University-affiliated Veterans Affairs Medical Center. PATIENTS All subjects were patients with stable COPD with no recent history of hospitalization or exacerbation of their lung disease. RESULTS This cohort of patients demonstrated a surprising frequency of desaturation below the recommended target SpO2 value (90%), which averaged approximately 25% of AOM recording time. There was wide variability among patients in the percentage of time SpO2 was below the target value (range, 3 to 67% of AOM recording time). Motion artifact on the AOM recordings was not a major problem; an average of 8% of the recording time was deleted secondary to artifacts in this patient cohort. CONCLUSIONS The results demonstrate that AOM is feasible and accurate with an acceptable level of motion artifact. These results also suggest that the standard approach for prescribing oxygen may lead to subtherapeutic SpO2 values in the outpatient setting. AOM holds promise as a tool to monitor the adequacy of oxygen prescriptions in the outpatient setting in patients with lung disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing need for long-term oxygen therapy: a comparison of conventional evaluation and measures of ambulatory oximetry monitoring.

BACKGROUND Appropriate identification of hypoxic patients with chronic obstructive pulmonary disease (COPD) is important because of the demonstrated survival benefit of long-term oxygen therapy (LTOT) and its associated cost. Resting oxygen saturation (measured via pulse oximetry [S(pO2)]) and lowest exercise S(pO2) (during a 6-min walk test) is the standard method of determining LTOT requireme...

متن کامل

Ambulatory pulse oximetry monitoring in Japanese COPD outpatients not receiving oxygen therapy

BACKGROUND It remains unknown whether desaturation profiles during daily living are associated with prognosis in patients with chronic obstructive pulmonary disease (COPD). Point measurements of resting oxygen saturation by pulse oximetry (SpO2) and partial pressure of arterial oxygen (PaO2) are not sufficient for assessment of desaturation during activities of daily living. A small number of s...

متن کامل

Effects of Pentoxifylline on Oxygenation and Exercise Tolerance in Patients with Severe Chronic Obstructive Pulmonary Disease

Background: It was hypothesized that the use of Pentoxifylline would increase arterial O2 saturation and increase exercise tolerance in patients with Chronic Obstructive Pulmonary Disease (COPD). Methods: We tested this hypothesis in 23 patients with COPD and pulmonary hypertension. Patients were randomized to receive Pentoxifylline or placebo, each for a 12-week period, in a prospectiv...

متن کامل

Reproducibility of the 6-minute walk test for ambulatory oxygen prescription.

BACKGROUND Ambulatory oxygen is frequently prescribed for patients with chronic obstructive pulmonary disease (COPD) who have oxygen desaturation </=88% during exercise. The 6-min walk test (6MWT) with continuous pulse oximetry monitoring is a common method to document this oxygen desaturation, but the reproducibility of this test in determining the need for ambulatory oxygen in patients with C...

متن کامل

Assessment of automated analysis of portable oximetry as a screening test for moderate-to-severe sleep apnea in patients with chronic obstructive pulmonary disease

BACKGROUND The coexistence of obstructive sleep apnea syndrome (OSAS) and chronic obstructive pulmonary disease (COPD) leads to increased morbidity and mortality. The development of home-based screening tests is essential to expedite diagnosis. Nevertheless, there is still very limited evidence on the effectiveness of portable monitoring to diagnose OSAS in patients with pulmonary comorbidities...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 116 2  شماره 

صفحات  -

تاریخ انتشار 1999