Determination of the AC Losses of Bi-2223 HTS Coils at 77 K at Power Frequencies Using a Mass Boil-Off Calorimetric Technique

نویسندگان

  • F. Darmann
  • S X. Dou
  • Frank Darmann
  • Shi Dou
  • Chris Cook
چکیده

A mass boil-off measurement system has been used to accurately measure and characterize the ac loss of high-temperature superconductor (HTS) coils at frequencies between 50 and 200 Hz, and in applied ac fields of up to 0.04 T. The mass boil-off calorimeter incorporated a glass cryostat, a copper field coil, and two mass flow meters. The response of the gas flow to a step change in the applied magnetic field was found to have a time constant of about 600 s. Under suitable experimental conditions, it was possible to measure the ac losses of coils with an accuracy of 0.3 W. The ac loss characteristics of an HTS pancake and two HTS solenoid coils are presented and the accuracy of mass flow calorimetry in liquid nitrogen is reported on.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Fractional Power Disk Shaped Motor with Superconducting Armature

A disk-shaped, double stator, induction motor with High Temperature Superconducting (HTS) field coils is proposed in this paper. Copper, typically used in windings of classic machines, limits current density allowed in field coils due to Joule effect losses. Also iron, which is used in magnetic circuits, limits the magnetic flux density obtained in the air gap due to saturation. The application...

متن کامل

An Active Homopolar Magnetic Bearing With High Temperature Superconductor Coils and Ferromagnetic Cores

A proof-of-feasibility demonstration showed that high temperature superconductor (HTS) coils can be used in a high-load, active magnetic bearing in liquid nitrogen. A homopolar radial bearing with commercially wound HTS (Bi 2223) bias and control coils produced over 200 lb (890 N) radial load capacity (measured nonrotating) and supported a shaft to 14000 rpm. The goal was to show that HTS coils...

متن کامل

Behavioural Modelling of High Temperature Superconducting Wires and Coils for Power Engineering Applications

Many aspects of the behaviour of high temperature superconducting (HTS) wires are well understood for dc applications. However, models of HTS suitable for use in circuit analysis by power engineers designing HTS applications are not readily available. This paper describes the initial development of suitable models for HTS wire. The V-I characteristics for wires carrying dc transport current can...

متن کامل

High-Temperature Superconducting RF Coils for 3T MRI

One way to reduce receiving coil noise in MRI scans is using non-resistive high-temperature superconducting (HTS) coils[1]. In this work we built a Bi-2223 tape HTS RF coil and tested its performance. Test results were in agreement with predictions, and a SNR gain of about 2.5 was obtained from the HTS tape coil over a conventional copper surface coil. Introduction Using superconducting coil in...

متن کامل

اثر جایگزینی Ba در جایگاه Sr در ابررسانای دمای بالای Bi-2223

Bi1.8Pb0.4Sr2-xBaxCa2.2Cu3Oy (x-0, 0.1, 0.2, 0.3) samples were prepared by a conventional solid state reaction method. The effect of Ba substitution at Sr site in Bi-2223 high-TC superconductors have been investigated by the XRD, SEM, dc electrical resistivity and ac susceptibility. XRD and SEM analysis indicated Ba substitution decreased temperature of 2223 phase formation. The highest 2223 ph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017