Analysis of linear electrode array EMG for assessment of hemiparetic biceps brachii muscles

نویسندگان

  • Bo Yao
  • Xu Zhang
  • Sheng Li
  • Xiaoyan Li
  • Xiang Chen
  • Cliff S. Klein
  • Ping Zhou
چکیده

This study presents a frequency analysis of surface electromyogram (EMG) signals acquired by a linear electrode array from the biceps brachii muscles bilaterally in 14 hemiparetic stroke subjects. For different levels of isometric contraction ranging from 10 to 80% of the maximum voluntary contraction (MVC), the power spectra of 19 bipolar surface EMG channels arranged proximally to distally along the muscle fibers were examined in both paretic and contralateral muscles. It was found that across all stroke subjects, the median frequency (MF) and the mean power frequency (MPF), averaged from different surface EMG channels, were significantly smaller in the paretic muscle compared to the contralateral muscle at each of the matched percent MVC contractions. The muscle fiber conduction velocity (MFCV) was significantly slower in the paretic muscle than in the contralateral muscle. No significant correlation between the averaged MF, MPF, or MFCV vs. torque was found in both paretic and contralateral muscles. However, there was a significant positive correlation between the global MFCV and MF. Examination of individual EMG channels showed that electrodes closest to the estimated muscle innervation zones produced surface EMG signals with significantly higher MF and MPF than more proximal or distal locations in both paretic and contralateral sides. These findings suggest complex central and peripheral neuromuscular alterations (such as selective loss of large motor units, disordered control of motor units, increased motor unit synchronization, and atrophy of muscle fibers, etc.) which can collectively influence the surface EMG signals. The frequency difference with regard to the innervation zone also confirms the relevance of electrode position in surface EMG analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Re-evaluation of EMG-torque relation in chronic stroke using linear electrode array EMG recordings

The objective was to re-evaluate the controversial reports of EMG-torque relation between impaired and non-impaired sides using linear electrode array EMG recordings. Ten subjects with chronic stroke performed a series of submaximal isometric elbow flexion tasks. A 20-channel linear array was used to record surface EMG of the biceps brachii muscles from both impaired and non-impaired sides. M-w...

متن کامل

Sound-Evoked Biceps Myogenic Potentials Reflect Asymmetric Vestibular Drive to Spastic Muscles in Chronic Hemiparetic Stroke Survivors

Aberrant vestibular nuclear function is proposed to be a principle driver of limb muscle spasticity after stroke. We sought to determine whether altered cortical modulation of descending vestibulospinal pathways post-stroke could impact the excitability of biceps brachii motoneurons. Twelve chronic hemispheric stroke survivors aged 46-68 years were enrolled. Sound evoked biceps myogenic potenti...

متن کامل

Abnormal force--EMG relations in paretic limbs of hemiparetic human subjects.

The relations between surface EMG and isometric force generated by elbow flexor muscles were compared in normal and paretic limbs of 17 hemiparetic human subjects. Similar analyses were performed on both arms of 11 normal subjects. In almost half of the hemiparetic subjects examined (8/17), the slope of the relation between elbow flexion force and surface EMG, measured over the biceps-brachiali...

متن کامل

ارزیابی ارگونومیک طرح جدید پوست کن دستی بر اساس روش الکترومیوگرافی

  Background and aims : In our daily lives hand tools are often used in many work situations. With respect to design characteristics, hand tools can be considered a risk factor when a high level of repetition are required or when awkward postures are adopted. Therefore attention to ergonomics design rules for hand tools is the most important factor in design process. With this in mind, the aim ...

متن کامل

Pathological stretch reflexes on the "good" side of hemiparetic patients.

The reflex EMG responses from a tendon tap or an imposed, medium amplitude (30 degrees), stretch at a range of stretch velocities have been recorded from the triceps and biceps muscles of normal human subjects and in both the affected and "unaffected" arms of hemiparetic patients under relaxed conditions. In the hemiparetic arm, exaggerated tendon jerks were, as expected, observed in both muscl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015