A loop-mediated isothermal amplification (LAMP) assay for Strongyloides stercoralis in stool that uses a visual detection method with SYTO-82 fluorescent dye.

نویسندگان

  • Matthew R Watts
  • Gregory James
  • Yasmin Sultana
  • Andrew N Ginn
  • Alexander C Outhred
  • Fanrong Kong
  • Jaco J Verweij
  • Jonathan R Iredell
  • Sharon C-A Chen
  • Rogan Lee
چکیده

An assay to detect Strongyloides stercoralis in stool specimens was developed using the loop-mediated isothermal amplification (LAMP) method. Primers were based on the 28S ribosomal subunit gene. The reaction conditions were optimized and SYTO-82 fluorescent dye was used to allow real-time and visual detection of the product. The product identity was confirmed with restriction enzyme digestion, cloning, and sequence analysis. The assay was specific when tested against DNA from bacteria, fungi and parasites, and 30 normal stool samples. Analytical sensitivity was to < 10 copies of target sequence in a plasmid and up to a 10(-2) dilution of DNA extracted from a Strongyloides ratti larva spiked into stool. Sensitivity was increased when further dilutions were made in water, indicative of reduced reaction inhibition. Twenty-seven of 28 stool samples microscopy and polymerase chain reaction positive for S. stercoralis were positive with the LAMP method. On the basis of these findings, the assay warrants further clinical validation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تشخیص و افتراق سریع فاسیولا هپاتیکا و فاسیولا ژیگانتیکا با استفاده از روش loop-mediated Isothermal Amplification

Background and purpose: Fasciola hepatica and Fasciola gigantica are common liver flukes which affect both human and livestock worldwide. In this study we evaluated the loop-mediated isothermal amplification (LAMP) assay for detection and discrimination of Fasciola species. Materials and methods: Fifty adults of Fasciola worms were isolated from sheep and cattle liver form abattoirs in Mazand...

متن کامل

A reverse transcriptase-loop mediated isothermal amplification assay (RT-LAMP) for rapid detection of bovine viral diarrhea virus 1 and 2

Bovine viral diarrhea virus (BVDV) is a pathogen that infects cattle, and is globally important. It causes substantial financial losses to the livestock industry. In the current study, a one-step reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP) assay was set up for rapid and efficient detection of BVDV. For this purpose, four primers were designed to recognize six distinct...

متن کامل

Loop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)

Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...

متن کامل

Rapid detection of infectious bursal disease by loop-mediated isothermal amplification for field analysis

Infectious bursal disease (IBD) is an immunosuppressive, acute and highly contagious illness of growing-poultry stock infected with infectious bursal disease virus (IBDV). It is common in Pakistan, causing potential economic losses throughout the year. The objective of the study is to propose a rapid, sensitive and specific diagnostic tool, and compare it with existing commonly used reverse tra...

متن کامل

Development of a Rapid and Sensitive Method for Detection of African Swine Fever Virus Using Loop-Mediated Isothermal Amplification

A loop-mediated isothermal amplification (LAMP) assay was developed for rapid, sensitive and specific detection of African swine fever virus (ASFV). A set of LAMP primers was designed based on the sequence of the ASFV gene K205R. Reaction temperature and time were optimized to 64 o C and 60 min, respectively. LAMP products were detected by agarose gel electrophoresis or visually with the additi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of tropical medicine and hygiene

دوره 90 2  شماره 

صفحات  -

تاریخ انتشار 2014