Accuracy of the cylinder approximation for susceptometric measurement of intravascular oxygen saturation.

نویسندگان

  • Cheng Li
  • Michael C Langham
  • Charles L Epstein
  • Jeremy F Magland
  • Jue Wu
  • James Gee
  • Felix W Wehrli
چکیده

Susceptometry-based MR oximetry has previously been shown suitable for quantifying hemoglobin oxygen saturation in large vessels for studying vascular reactivity and quantification of global cerebral metabolic rate of oxygen utilization. A key assumption underlying this method is that large vessels can be modeled as long paramagnetic cylinders. However, bifurcations, tapering, noncircular cross-section, and curvature of these vessels produce substantial deviations from cylindrical geometry, which may lead to errors in hemoglobin oxygen saturation quantification. Here, the accuracy of the "long cylinder" approximation is evaluated via numerical computation of the induced magnetic field from 3D segmented renditions of three veins of interest (superior sagittal sinus, femoral and jugular vein). At a typical venous oxygen saturation of 65%, the absolute error in hemoglobin oxygen saturation estimated via a closed-form cylinder approximation was 2.6% hemoglobin oxygen saturation averaged over three locations in the three veins studied and did not exceed 5% for vessel tilt angles <30° at any one location. In conclusion, the simulation results provide a significant level of confidence for the validity of the cylinder approximation underlying MR susceptometry-based oximetry of large vessels.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and precision of MR blood oximetry based on the long paramagnetic cylinder approximation of large vessels.

An accurate noninvasive method to measure the hemoglobin oxygen saturation (%HbO(2)) of deep-lying vessels without catheterization would have many clinical applications. Quantitative MRI may be the only imaging modality that can address this difficult and important problem. MR susceptometry-based oximetry for measuring blood oxygen saturation in large vessels models the vessel as a long paramag...

متن کامل

Validity of Peripheral Capillary Oxygen Saturation and Normal Mixed Venous Oxygen Tension in Measurement of O2 Content

Background The change in venous oxygen saturation occurs earlier, and even its reduction is faster than arterial oxygen saturation. The aim of this study was to validate SvO2 and PvO2 for O2 content measurement in children hospitalized w...

متن کامل

تأثیر ساکشن لوله داخل نای بر وضعیت همودینامیک واکسیژناسیون خون شریانی

  Background and Aim: Intratracheal suctioning is a standard method of nursing care for intubated patients with the aim of cleaning airway for good oxygenation. The aim of this study was to evaluate the effects of intratracheal suctioning on blood pressure, heart rate, and arterial oxygen saturation.   Materials and Methods: This was a semi-experimental research in which the patients admitted t...

متن کامل

Investigation of the Effect Soil particles size on the Currency Time Domain Reflectometry for water content measurement

This study carried out on the provided textures at laboratory. The provided textures were infusedinside the PVC cylinder with 30cm height and 25cm diameter. The studied textures were loamysand, sandy loam, sandy clay-loam, clay loam and clay. After 24 hours of saturation, the soil watercontent of the samples was measured by oven-dry gravimetric and TDR methods. For each texturesat any stage of ...

متن کامل

In vitro measurements of absolute blood oxygen saturation using pulsed near-infrared photoacoustic spectroscopy: accuracy and resolution.

Pulsed photoacoustic spectroscopy was used to measure blood oxygen saturation in vitro. An optical parametric oscillator laser system provided nanosecond excitation pulses over the wavelength range 740-1040 nm which were used to generate photoacoustic signals in a cuvette through which a saline suspension of red blood cells was circulated. The signal amplitude and the effective attenuation coef...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 67 3  شماره 

صفحات  -

تاریخ انتشار 2012