Cortical Magnification within Human Primary Visual Cortex Correlates with Acuity Thresholds

نویسندگان

  • Robert O. Duncan
  • Geoffrey M. Boynton
چکیده

We measured linear cortical magnification factors in V1 with fMRI, and we measured visual acuity (Vernier and grating) in the same observers. The cortical representation of both Vernier and grating acuity thresholds in V1 was found to be roughly constant across all eccentricities. We also found a within-observer correlation between cortical magnification and Vernier acuity, further supporting claims that Vernier acuity is limited by cortical magnification in V1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tactile hyperacuity thresholds correlate with finger maps in primary somatosensory cortex (S1).

Behavioral tactile discrimination thresholds were compared with functional magnetic resonance imaging measurements of cortical finger representations within primary somatosensory cortex (S1) for 10 human subjects to determine whether cortical magnification in S1 could account for the variation in tactile hyperacuity thresholds of the fingers. Across 10 subjects, the increase in tactile threshol...

متن کامل

Resolution, separation of retinal ganglion cells, and cortical magnification in humans

We present direct comparisons of resolution thresholds and quantitative estimates of retinal ganglion cell separation in humans with reported functional magnetic resonance imaging estimates of the human linear cortical magnification factor. Measurements of resolution thresholds (MAR), retinal ganglion cell (GC) densities, and linear cortical magnification factor (M) values were taken from the l...

متن کامل

Position sense of the peripheral retina.

Position acuity was measured over a wide range of eccentricities, from 3 min to 10 deg in the horizontal meridian, by using both a three-dot bisection task and a three-dot vernier task. A foveal fixation dot appeared for 1 sec before an outer pair of test dots was flashed for 200 msec. Bisection and vernier tasks were used to measure position acuity in the radial and tangential directions, resp...

متن کامل

Contrast thresholds for identification of numeric characters in direct and eccentric view.

Aubert and Foerster (1857) are frequently cited for having shown that the lower visual acuity of peripheral vision can be compensated for by increasing stimulus size. This result is seemingly consistent with the concept of cortical magnification, and it has been confirmed by many subsequent authors. Yet it is rarely noted that Aubert and Foerster also observed a loss of the "quality of form." W...

متن کامل

Cortical sources of Vernier acuity in the human visual system: An EEG-source imaging study

Vernier acuity determines the relative position of visual features with a precision better than the sampling resolution of cone receptors in the retina. Because Vernier displacement is thought to be mediated by orientation-tuned mechanisms, Vernier acuity is presumed to be processed in striate visual cortex (V1). However, there is considerable evidence suggesting that Vernier acuity is dependen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neuron

دوره 38  شماره 

صفحات  -

تاریخ انتشار 2003