Detection and characterization of very small cerebral aneurysms by using 2D and 3D helical CT angiography.

نویسندگان

  • J Pablo Villablanca
  • Reza Jahan
  • Parizad Hooshi
  • Silvester Lim
  • Gary Duckwiler
  • Aman Patel
  • James Sayre
  • Neil Martin
  • John Frazee
  • John Bentson
  • Fernando Viñuela
چکیده

BACKGROUND AND PURPOSE Many cases of subarachnoid hemorrhage are due to rupture of small cerebral aneurysms. Our purpose was to evaluate the usefulness of helical CT angiography (CTA) in the detection and characterization of very small (<5 mm) intracranial aneurysms. METHODS One hundred eighty consecutive patients underwent CTA for suspected intracranial aneurysms. All aneurysms prospectively detected by CTA were confirmed by digital subtraction angiography (DSA) or at surgery. CT angiograms and digital subtraction angiograms were reviewed by two independent blinded radiologists who performed aneurysm detection, quantitation, and characterization using 2D multiplanar reformatted and 3D volume-rendering techniques. RESULTS Fifty-one patients harboring 41 very small intracranial aneurysms were included in this series. Eighty-one percent (33 of 41 aneurysms) were </=4 mm in maximal diameter, and 37% (15 of 41 aneurysms) were </=3 mm in maximal diameter. Sensitivity of CTA for very small intracranial aneurysm detection ranged from 98% to 100% (95% confidence intervals, 0.871, 0.999, 0.914, and 1.0), compared with 95% for DSA. The specificity of CTA and DSA for very small intracranial aneurysms was 100% (26 of 26 aneurysms). Positive predictive value ranged from 98% to 100%. Negative predictive value ranged from 96% to 100%. Accuracy of CTA for detection of very small intracranial aneurysms was 99% and 100% (kappa = 0.969 - 1.0 +/- 0.1221). Forty-eight percent of aneurysms were detected in the presence of subarachnoid hemorrhage. CONCLUSION The sensitivity of CTA for the detection of cerebral aneurysms </=5 mm is higher than that of DSA, with equal specificity and high interoperator reliability. High quality, noninvasive CTA aneurysm detection and characterization can be performed using routine clinical CT scanners and commercially available image processing workstations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-section CT angiography for detection of cerebral aneurysms.

BACKGROUND AND PURPOSE Multi-section CT has great potential for use in vascular studies. Our purpose was to determine the accuracy of multi-section CT angiography in detecting cerebral aneurysms compared with digital subtraction angiography or surgery. METHODS One hundred consecutive patients who underwent multi-section CT angiography and either digital subtraction angiography or surgery were...

متن کامل

Subtraction CT angiography with controlled-orbit helical scanning for detection of intracranial aneurysms.

PURPOSE Our goal was to evaluate the utility of subtraction three-dimensional CT angiography for the detection of intracranial aneurysms. METHODS Thirty-six patients with intracranial aneurysms were examined using newly devised controlled-orbit helical scanning and conventional angiography. Three-dimensional CT angiograms and subtraction 3-D CT angiograms were compared with conventional angio...

متن کامل

Case series of 64 slice computed tomography-computed tomographic angiography with 3D reconstruction to diagnose symptomatic cerebral aneurysms: new standard of care?

CT angiography (CTA) has improved significantly over the past few years such that the reconstructed images of the cerebral arteries may now be equivalent to conventional digital angiography. The new technology of 64 slice multi-detector CTA can reconstruct detailed images that can reliably identify small cerebral aneurysms, even those <3mm. In addition, it is estimated that CT followed by lumba...

متن کامل

Cerebral aneurysms: detection and delineation using 3-D-CT angiography.

PURPOSE We compared three-dimensional image (3-D-CT) angiography with conventional angiography to determine the clinical usefulness of this technique. MATERIALS AND METHODS We studied 15 patients with cerebral aneurysms using dynamic CT with intravenous injection of contrast material and reconstructed 3-D-CT angiography. RESULTS 3-D-CT angiography could be performed in conjunction with stan...

متن کامل

CT angiography with three-dimensional techniques for the early diagnosis of intracranial aneurysms. Comparison with intra-arterial DSA and the surgical findings.

INTRODUCTION Cerebral CT angiography (CTA) is an established method applied to both the detection and treatment planning of intracranial aneurysms. The aim of our study was to compare CTA and digital subtraction angiography (DSA) findings with the surgical results mainly in patients with acute SAH and to evaluate the clinical usefulness of CTA. MATERIALS AND METHODS During the last 2 years, 8...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2002