Import of radiation phenomena of electrons and therapeutic low-level laser in regard to the mitochondrial energy transfer.
نویسندگان
چکیده
OBJECTIVE The authors describe a consistent theoretical model of the cellular energy transfer (respiratory chain) by taking into consideration the radiation phenomena of electrons and therapeutic low level laser. SUMMARY BACKGROUND DATA Biochemical models of the cellular energy transfer regard the classical corpuscular aspect of electrons as the responsible energy carriers, thereby ignoring the wave-particle dualism of the electrons and the import of radiation energy in this process. METHODS The authors show the influence of radiation phenomena on the cellular energy transfer, explaining consistently some of the intermediate steps of this complex process. RESULTS Because of the inherent wave-particle dualism of the electrons, it is appropriate to regard radiation phenomena to explain the cellular energy transfer. The classical biochemical models use only the particle part of the electrons as energy carriers. The connection between energy transport by radiation and the order in structures may be understood if, for instance, structurally bound energy is released during the dissolution of structures (oxidation of foodstuffs) or is again manifested (final reduction of oxygen to water). With a attention to the energy values relevant for the respiratory chain, the import of electromagnetic radiation of characteristic ranges of wavelengths on the cellular energy transfer becomes evident. Depending on its wavelength, electromagnetic radiation in the form of light can stimulate macromolecules and can initiate conformation changes in proteins or can transfer energy to electrons. Low level laser from the red and the near infrared region corresponds well with the characteristic energy and absorption levels of the relevant components of the respiratory chain. This laser stimulation vitalizes the cell by increasing the mitochondrial ATP(adenosine-tri-phosphate)-production. CONCLUSIONS With regard to radiation phenomena and its inhanced electron flow in the cellular energy transfer (respiratory chain), it is possible to explain the experimentally found increase of ATP-production by means of low-level laser light on a cellular level. Intense research for this biostimulative effect is still necessary.
منابع مشابه
Role of low level laser in ameliorating the damaging effects of gamma irradiation on mice liver
Background: Exposure to ionizing radiation is inevitable. Using of low-level laser therapy (LLLT) stimulates tissue repair and reduces inflammation. The objective of the present study aimed at evaluating the therapeutic efficacy of Helium-Neon (He-Ne) laser in stimulating the reparative processes in the liver of mice after whole body gamma-irradiation (WBγ-I). Materials and Methods: Two hundred...
متن کاملشبیهسازی ذرهای شتاب دادن الکترونها در پلاسمای کم چگال
One of the interesting Laser-Plasma phenomena, when the laser power is high and ultra intense, is the generation of large amplitude plasma waves (Wakefield) and electron acceleration. An intense electromagnetic laser pulse can create plasma oscillations through the action of the nonlinear pondermotive force. electrons trapped in the wake can be accelerated to high energies, more than 1 TW. Of t...
متن کاملCalculation and evaluation of energy deposition and S-value caused by low-energy electrons in a multicellular model using Geant4-DNA
Today, targeted radiation therapy (TRT) methods for cancer treatment, besides the goal of completely destroying the target tumor, attempts to prevent nearby healthy cells from exposure to ionizing radiation as far as possible. Hence, short-range charged particles, such as low-energy electrons that are suited to achieving these two goals together, play an important role in TRT and so, adoption o...
متن کاملThe Importance of absorbed dose in medical applications
Radiation damage depends on energy absorption, and is approximately proportional to the absorbed energy density in the tissue. In external radiation consideration with a certain energy flux, the amount of absorbed dose in each point of the tissue depends on the type of radiation, the radiation energy, the depth of the place of receipt, and the main components of the absorber environment. The ab...
متن کاملمشخصه جریان- ولتاژ یک دیود تونل زنی تشدیدی تحت تابش موج الکترومغناطیسی
In this paper, current-voltage characteristic of a resonant tunneling diode under electromagnetic radiation has been calculated and compared with the results when there is no electromagnetic radiation. For calculating current -voltage characteristic, it is required to calculate the transmission coefficient of electrons from the well and barrier structures of this device. For calculating the tr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical laser medicine & surgery
دوره 16 3 شماره
صفحات -
تاریخ انتشار 1998