Defibrillation testing is not required during routine ICD implantation.

نویسندگان

  • Valentina Kutyifa
  • Arthur J Moss
چکیده

Sudden cardiac death (SCD) is a major cause of mortality throughout the world, accounting for 300 000 deaths per year in the USA. The introduction of the implantable cardioverter defibrillator (ICD) in the 1980s significantly reduced the risk of SCD by terminating life-threatening ventricular tachyarrhythmias. Subsequent clinical trials confirmed the survival benefit with implanted ICDs in at-risk cardiac patients. Since the beginning, defibrillation threshold (DFT) testing has been an integral part of the ICD implantation procedure to ascertain detection and termination of ventricular tachyarrhythmias. DFT testing often involves multiple ventricular fibrillation (VF) induction and defibrillation, imposing a significant burden on the implanting team and, foremost, the patient. However, the view on the routine use of DFT testing has been challenged by a recent investigation on DFT testing during ICD implantation. In this issue of the journal, Bänsch et al. present another prospective, randomized, parallel group, multicentre non-inferiority trial, NORDIC ICD, designed to test the hypothesis that shock efficacy during follow-up is not impaired in patients implanted without DFT during first ICD implantation. In this study, 1077 patients were randomly assigned to first time ICD implantation with (n 1⁄4 540) or without (n 1⁄4 537) DFT testing. During a median follow-up of 22.8 months, the first shock efficacy for all true ventricular tachycardia and fibrillation (VT/VF) was non-inferior in patients with an ICD implanted without DFT testing, with a difference in first shock efficacy of 3.0% in favour of the no DFT arm [95% confidence interval (CI) –3.0% to 9.0%, P , 0.001 for non-inferiority]. There was a trend towards a higher rate of procedure-related serious adverse events within 30 days in the DFT testing arm (112 vs. 89 events, P 1⁄4 0.095). The authors are to be applauded for conducting a well-designed randomized clinical trial with enrolment of over a thousand patients to extend our knowledge further on the need for DFT during first ICD implantation. These findings further confirm the results of another recently published, large randomized clinical trial, the Shockless Implant Evaluation (SIMPLE) study by Healey et al. There are, however, differences between the two clinical trials. While in the SIMPLE trial, the endpoint was the composite of failed first appropriate clinical shock from the ICD or arrhythmic death, the NORDIC ICD trial utilized the endpoint of first shock efficacy for true VT/VF episodes. However, it is reassuring to know that in NORDIC ICD, there was no significant increase in all-cause mortality or arrhythmic death in the no DFT testing arm. The authors actually report a significantly higher rate of combined arrhythmic and sudden unknown deaths in the DFT testing group as compared with no DFT testing (P 1⁄4 0.03). However, these findings have to be taken with a ‘pinch of salt’, since the event rate of combined arrhythmic and sudden unknown deaths was extremely low in the trial (DFT testing arm 11 patients, 2% compared with 3 patients, 0.6% in the no DFT testing arm). The authors suspect myocardial damage as the underlying pathomechanism for the increased risk of arrhythmic and sudden unknown death, recently suggested by a small study showing increased levels of brain natriuretic peptide (BNP) and troponin levels in ICD patients after DFT testing. However, a substudy from our Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT) showed that even increasing the number of ICD shocks and delivery of high energy ICD shocks during DFT testing were not associated with increased risk for heart failure or death. This deserves further investigation in prospective large patient cohorts, such as in the currently ongoing pre-specified substudy on troponin levels after DFT testing in the SIMPLE trial. Furthermore, the NORDIC ICD trial had a shorter follow-up as compared with SIMPLE (22.8 vs. 37 months) and, although the patient populations in the two studies were comparable, the overall mortality rate was lower in NORDIC ICD, indicative of a less sick patient cohort. The evidence in favour of no routine DFT testing in most ICD patients is now significant. However, generalization of these findings to all ICD implantations would be a mistake (see Figure 1). It is

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraoperative Defibrillation Testing of Subcutaneous Implantable Cardioverter‐Defibrillator Systems—A Simple Issue?

BACKGROUND The results of the recently published randomized SIMPLE trial question the role of routine intraoperative defibrillation testing. However, testing is still recommended during implantation of the entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) system. To address the question of whether defibrillation testing in S-ICD systems is still necessary, we analyzed the dat...

متن کامل

Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators: the NORDIC ICD randomized clinical trial

AIMS This trial was designed to test the hypothesis that shock efficacy during follow-up is not impaired in patients implanted without defibrillation (DF) testing during first implantable cardioverter-defibrillator (ICD) implantation. METHODS AND RESULTS Between February 2011 and July 2013, 1077 patients were randomly assigned (1 : 1) to first time ICD implantation with (n = 540) or without (...

متن کامل

ICD Shock, Not Ventricular Fibrillation, Causes Elevation of High Sensitive Troponin T after Defibrillation Threshold Testing—The Prospective, Randomized, Multicentre TropShock-Trial

BACKGROUND The placement of an implantable cardioverter defibrillator (ICD) has become routine practice to protect high risk patients from sudden cardiac death. However, implantation-related myocardial micro-damage and its relation to different implantation strategies are poorly characterized. METHODS A total of 194 ICD recipients (64±12 years, 83% male, 95% primary prevention of sudden cardi...

متن کامل

Defibrillation testing: should the paradigm shift?

In 3 decades of clinical use of the implantable cardioverter-defibrillator (ICD), defibrillation threshold (DFT) testing has remained an integral part of the implantation procedure. The prevailing rationale for the routine evaluation of DFTs has been to ensure appropriate sensing of ventricular fibril-lation, system integrity, and effective defibrillation (1–3). Early ICD systems using monophas...

متن کامل

Clinical evaluation of defibrillation testing in an unselected population of 2,120 consecutive patients undergoing first implantable cardioverter-defibrillator implant.

OBJECTIVES The purpose of this study is to assess the effectiveness of defibrillation testing (DT) in patients undergoing implantable cardioverter-defibrillator (ICD) insertion. BACKGROUND Although DT is considered a standard procedure during ICD implantation, its usefulness has not been definitively proven. METHODS The SAFE-ICD (Safety of Two Strategies of ICD Management at Implantation) s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 36 37  شماره 

صفحات  -

تاریخ انتشار 2015