Reproducibility of a standardized quantitative analysis using fixed regions of interest to differentiate movement disorders on 123I-FP-CIT SPECT.
نویسندگان
چکیده
UNLABELLED The present prospective study evaluated the diagnostic value of a standardized analysis of (123)I-N-omega-(fluoropropyl)-2beta-carbomethoxy-3beta-(4-iodophenyl)tropane (FP-CIT) SPECT studies acquired on a triple-head gamma-camera for patients with clinically uncertain movement disorders having tremor as the most striking feature. METHODS (123)I-FP-CIT studies were performed on 52 consecutive patients (27 male and 25 female; mean age, 49.2 y; range, 17-80 y) who had a clinical diagnosis of Parkinson's disease (PD) (n = 21), hypokinetic rigid syndrome (n = 19), dystonia (n = 8), or essential tremor (n = 4). In all patients, the final diagnosis was based on a thorough clinical examination, the family history, and a 2-y follow-up. Two independent technologists analyzed (123)I-FP-CIT studies using a standardized quantitative method applying both fixed regions of interest (ROIs) and manually drawn ROIs. The mean values from both methods were compared using the Student t test, and the intra- and intertechnologist variabilities were tested. RESULTS In patients with PD, all ratios were significantly lower (P < 0.001) than those in patients with other movement disorders. No significant differences were found between the other groups tested. The manual method resulted in significantly lower values than did the standardized method (P < 0.001) and, for the putamen, showed significant differences between technologists. The standardized method showed no significant differences between technologists. The intra- and intertechnologist variabilities for this method were 0.14 +/- 0.13 (confidence value, 2.4%) and 0.19 +/- 0.18 (confidence value, 3.1%), respectively, whereas the intraclass correlation coefficients were 0.99 for 1 technologist and 0.98 for the 2 independent technologists. CONCLUSION Our data confirm that (123)I-FP-CIT SPECT has value in the differentiation of PD from other movement disorders. Acquisition using a triple-head gamma-camera and subsequent standardized analysis using fixed ROIs result in good intra- and intertechnologist agreement and can easily be applied in clinical practice.
منابع مشابه
Improvement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database
Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the util...
متن کاملCost-effectiveness of 123I-FP-CIT SPECT in the differential diagnosis of essential tremor and Parkinson's disease in Italy.
Economic evaluation (Italian NHS perspective) modeling (123)I-FP-CIT SPECT (DaTSCAN) compared to clinical judgment alone for differentiating essential tremor (ET) from Parkinson's Disease (PD). A 5-year Markov model was constructed to assess the cost-effectiveness of (123)I-FP-CIT SPECT to differentiate ET from PD in patients referred to a movement disorder specialist in Italy. Published data a...
متن کاملThe impact of reconstruction and scanner characterisation on the diagnostic capability of a normal database for [123I]FP-CIT SPECT imaging
BACKGROUND The use of a normal database for [123I]FP-CIT SPECT imaging has been found to be helpful for cases which are difficult to interpret by visual assessment alone, and to improve reproducibility in scan interpretation. The aim of this study was to assess whether the use of different tomographic reconstructions affects the performance of a normal [123I]FP-CIT SPECT database and also wheth...
متن کاملValidation of Optimum ROI Size for 123I-FP-CIT SPECT Imaging Using a 3D Mathematical Cylinder Phantom
Objective(s): The partial volume effect (PVE) of single-photon emission computed tomography (SPECT) on corpus striatum imaging is caused by the underestimation of specific binding ratio (SBR). A large ROI (region of interest) set using the Southampton method is independent of PVE for SBR. The present study aimed to determine the optimal ROI size with contrast and SBR for striatum images and val...
متن کاملAccurate differentiation of parkinsonism and essential tremor using visual assessment of [123I]-FP-CIT SPECT imaging: the [123I]-FP-CIT study group.
OBJECTIVE To evaluate whether visual assessment of [123I]-FP-CIT (DaTSCAN, Nycomed Amersham, plc) single photon emission computerized tomography (SPECT) images can differentiate between parkinsonism and essential tremor (ET). METHODS [123I]-FP-CIT SPECT imaging was conducted in a six-center study of 158 patients with a clinical diagnosis of parkinsonism compared with 27 ET cases and 35 health...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 35 1 شماره
صفحات -
تاریخ انتشار 2007