Maternal and neonatal effects of adding morphine to low-dose bupivacaine for epidural labor analgesia.
نویسندگان
چکیده
AIM Labor is one of the most painful experiences a woman may face during her lifetime. One of the most effective methods used for eliminating this pain is epidural analgesia. The aim of this study to determine the impact of adding morphine to low-dose bupivacaine epidural anesthesia on labor and neonatal outcomes, and maternal side effects. MATERIALS AND METHODS This is a prospective randomized double-blind study comparing two regimens of anesthetic agents used for epidural anesthesia in labor. A total of 120 pregnant women were randomized into two groups with 60 subjects in each study arm. A catheter was inserted, and 0.1% bupivacaine + 2 μg/mL fentanyl in 15 mL saline were given to Group bupivacaine-fentanyl (Group BF), while 0.0625% bupivacaine + 2 μg/ml fentanyl + 2 mg morphine in 15 mL saline were given to Group bupivacaine-fentanyl-morphine (Group BFM) with no test dosing from the needle. No morphine was added to the subsequent epidural injections in Group BFM. RESULTS The total dose of bupivacaine was significantly lower in Group BFM relative to Group BF (P = 0.0001). The visual analogu scalescores at 15, 30, and 45 min were significantly lower in Group BF compared to thosein Group BFM (P = 0.0001, P = 0.001, and P = 0.006, respectively). The second stage of labor was significantly shorter in Group BFM relative to Group BF (P = 0.027 and P = 0.003, respectively). The satisfaction with analgesia following the first dose was higher in the nonmorphine group (P = 0.0001). However, maternal postpartum satisfaction was similar in both groups. Either nausea or vomiting was recorded in eight patients in Group BFM. CONCLUSION We believe that epidural analgesia comprised of a low-dose local anaesthetic and 2 mg morphine provides a painless labor that significantly reducesthe use of local anesthetic without changing the efficiency of the analgesic, ensuring the mother's satisfaction without leading to an adverse effect on the mother or foetus, while mildly (but significantly) shortening the second stage of labor.
منابع مشابه
EFFECTS OF EPIDURAL ANALGESI A WITH LOW-DOSE BUPIVACAINE AND FENTANYL ON THE PROGRESS OF LABOR AND MODE OF DELIVERY
Background and Objective: Epidural analgesia (EA) has been used to relieve labor pain in many obstetric units, yet controversy persists about its effect on progress and outcome in labor. The purpose of the current study was to evaluate the effect of EA on the rate of cervical dilation and myometrial contractility. Methods: In a 6-month period, 36 women who received standardized EA were mat...
متن کاملMaternal and neonatal fentanyl and bupivacaine concentrations after epidural infusion during labor.
Labor analgesia using continuous epidural infusions of low-dose bupivacaine and fentanyl may be maintained for many hours. We examined the potential for drug accumulation in both mother and neonate after these long-term infusions. Pregnant women receiving a 10-mL/h continuous infusion of labor analgesia with 0.125% bupivacaine and 2 micrograms/mL of fentanyl were evaluated. Maternal venous and ...
متن کاملComparison of bupivacaine and ropivacaine in combination with fentanyl used for walking epidural anesthesia in labor
OBJECTIVE Effective pain relief during labor is essential to reduce maternal and perinatal morbidity arising due to pain-induced maternal sympathetic activation, and to avoid unnecessary cesarean sections performed due to maternal anxiety. Walking epidural analgesia on labor reveals lower pain scores, leading to higher maternal satisfaction with better cardiovascular and pulmonary physiology. D...
متن کاملبررسی اثرات مادری و نوزادی افزودن میدازولام به بوپیواکایین تحت بیحسی توأم اسپینال- اپیدورال در سزارین انتخابی
Background and Aim: Epidural-spinal anesthesia is one of the modern methods used to establish adequate anesthesia in cesarean section. In order to reduce these adverse effects different drugs are added to the anesthetic solution. The main aim of this article is evaluation of maternal and neonatal effects of adding Midazolam to Bupivacaine under combined spinal-epidural anesthesia in electi...
متن کاملRegression of sensory analgesia with lumbar epidural catheters.
TO the Editor-I read with interest the study by Boylan et al.' comparing epidural bupivacaine-morphine analgesia with patient-controlled analgesia after abdominal aortic surgery. However, I have a major concern. After a loading dose of 1 0 ml of 2% lidocaine followed by 15 ml of 0.25%) bupivacaine via a lumbar epidural catheter, sensory block in the epidural group was probably at an adequate th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nigerian journal of clinical practice
دوره 17 2 شماره
صفحات -
تاریخ انتشار 2014