Beam Intensity Profile Monitor

نویسندگان

  • D. R. Walz
  • E. J. Seppi
چکیده

This paper describes an intercepting beam intenSity profile and position monitor which was developed at SLAC. It has excellent spatial resolution as well as signal efficiency. The instrument utilizes the electromagnetic cascade shower emission effect. Net charge leakage signals comparable in magnitude to the intercepted beam current are easily obtainable. The latest model of the instrument is described. It consists of an array of closely spaced 0.0025 cm thick tungsten ribbons which are 2 r. 1. long in beam direction. Experimental results as well as application of the basic idea to four different instruments are discussed. The instruments are: (1) a spectrum analyzer, (2) a vertical beam position monitor, (3) a ring inflection monitor for the SLAC electron-positron storage ring project, and (4) an accelerator beam phase space measurer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thin Foil-based Secondary Emission Monitor for Low Intensity, Low Energy Beam Profile Measurements∗

A foil-based secondary emission monitor (SEM) was developed for beam profile measurements at the Ultra-low energy Storage Ring (USR) that will be installed at the future Facility for Low-energy Antiproton and Ion Research (FLAIR) in Darmstadt, Germany. Simulations of the optimised design of the monitor are presented. Furthermore, its usability for the low energy antiproton (p̄) beam profile moni...

متن کامل

Beam Characteristics at Low Dose Monitor Unit Settings for Vero4DRT

The stability of delivery of low monitor unit (MU) setting is important especially for step-andshoot intensity-modulated radiotherapy (IMRT), because the nature of the technique is inherent to repeat beam on/off according to the number of the segments. This study evaluates the dose linearity and profile flatness/symmetry under low MU settings for Vero4DRT, a new linear-accelerator based irradia...

متن کامل

Development of Pair Monitor

Figure 1: A schematic view of the forward region. The pair monitor will be located in front of the BeamCal, where is about 400 cm from IP. At ILC, measurement of the beam profile at IP is important to keep high luminosity of 2 × 10 cms. The beam size at IP is 639 nm, 5.7 nm, and 300 μm for horizontal (σX), vertical (σY), and longitudinal beam size (σZ), respectively. Since the beam size, especi...

متن کامل

Beam Transverse Profile Monitors for Ifmif-eveda

In the framework of the IFMIF-EVEDA project, a high deuteron beam intensity (125 mA 9 MeV) prototype accelerator will be built and tested at Rokkasho (Japan). CEA-Saclay group and CIEMAT-Madrid (Spain) are responsible for the beam instrumentation from the ion source to the beam dump. One of the most challenging diagnostic is the Beam Transverse Profile Monitor. Two kinds of monitor are investig...

متن کامل

3d Density Scans of a Supersonic Gas Jet for Beam Profile Monitor

Recently, we have developed a novel beam profile monitor based on a supersonic gas jet. It can be applied to some extreme situation while other methods are not applicable such as for the high intensity and energy beams with destructive power and for the short life beam which requires minimum interference. The resolution of this monitor depends on the jet thickness and homogeneity, and thus we d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1971