Placement of trans-sternal wires according to an ellipsoid pressure vessel model of sternal forces.

نویسندگان

  • Aaron R Casha
  • Alex Manché
  • Marilyn Gauci
  • Marie-Therese Camilleri-Podesta
  • Pierre Schembri-Wismayer
  • Zdenka Sant
  • Ruben Gatt
  • Joseph N Grima
چکیده

Dehiscence of median sternotomy wounds remains a clinical problem. Wall forces in thin-walled pressure vessels can be calculated by membrane stress theory. An ellipsoid pressure vessel model of sternal forces is presented together with its application for optimal wire placement in the sternum. Sternal forces were calculated by computational simulation using an ellipsoid chest wall model. Sternal forces were correlated with different sternal thicknesses and radio-density as measured by computerized tomography (CT) scans of the sternum. A comparison of alternative placement of trans-sternal wires located either at the levels of the costal cartilages or the intercostal spaces was made. The ellipsoid pressure vessel model shows that higher levels of stress are operative at increasing chest diameter (P < 0.001). CT scans show that the thickness of the sternal body is on average 3 mm and 30% thicker (P < 0.001) and 53% more radio-dense (P < 0.001) at the costal cartilage levels when compared with adjacent intercostal spaces. This results in a decrease of average sternal stress from 438 kPa at the intercostal space level to 338 kPa at the costal cartilage level (P = 0.003). Biomechanical modelling suggests that placement of trans-sternal wires at the thicker bone and more radio-dense level of the costal cartilages will result in reduced stress.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sternal plating for primary and secondary sternal closure; can it improve sternal stability?

BACKGROUND Sternal instability with mediastinitis is a very serious complication after median sternotomy. Biomechanical studies have suggested superiority of rigid plate fixation over wire cerclage for sternal fixation. This study tests the hypothesis that sternal closure stability can be improved by adding plate fixation in a human cadaver model. METHODS Midline sternotomy was performed in 1...

متن کامل

Comparison of the sternal wires and sternal cable in closure of the sternum during cardiac surgery

Corresponding author: Yücel Özen, M.D. Kartal Koşuyolu Yüksek İhtisas Eğitim ve Araştırma Hastanesi Kalp ve Damar Cerrahisi Kliniği, 34844 Cevizli, Kartal, İstanbul, Turkey. Tel: +90 505 872 76 56 e-mail: [email protected] Objectives: This study aims to compare the effectiveness of the sternal cable system (Cable group) with the standard monofilament system (Wire group) in the sternal closu...

متن کامل

Potential risk of sternal wires.

OBJECTIVE To understand the potential fracture mechanism of sternal wires, we collected extracted stainless steel sternal wires from patients with sternal dehiscence following open-heart operations. Surface alterations and fractured ends of sternal wires were inspected and analyzed. METHODS Eight fractured and 12 non-fractured wires extracted from five patients (closure method: figure-of-eigh...

متن کامل

Sternal Talon, a novel repair for sternal dehiscence

Sternal dehiscence is a recognised complication after median sternotomy, occurring in 0.5-5% of cases with or without infection. A 72-year-old man presenting with collapse and ventricular tachycardia was investigated for a possible acute cardiac event 2 years after coronary artery bypass grafting for ischemic heart disease. Work-up chest X-ray showed displacement of all sternal wires, and compu...

متن کامل

Multidimensional Sternal Fixation to Overcome a “Floating” Sternum

This case report describes the repair of a complete sternal dehiscence of the lower right sternum using sternal wires, manubrial plates, and a Talon closure device for rigid, multidimensional sternal fixation. Sternal dehiscence is a rare but significant cause of morbidity for patients undergoing median sternotomy. The risk factors for this complication are well described and although sternal w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 14 3  شماره 

صفحات  -

تاریخ انتشار 2012