Memr Measurements Obtained with a Pure-tone Probe

نویسندگان

  • Kim S. Schairer
  • M. Patrick Feeney
  • Chris A. Sanford
چکیده

43S Middle ear muscle reflex (MEMR) measurements have been a part of the standard clinical immittance test battery for decades as a cross-check with the behavioral audiogram and as a way to separate cochlear from retrocochlear pathologies. MEMR responses are measured in the ear canal by using a probe stimulus (e.g., single frequency or broadband noise) to monitor admittance changes elicited by a reflex-activating stimulus. In the clinical MEMR procedures, one test yields changes in a single measurement (i.e., admittance) at a single pure tone (e.g., 226 or 1000 Hz). In contrast, for the wideband acoustic immittance (WAI) procedure, one test yields information about multiple measurements (e.g., admittance, power reflectance, absorbance) across a wide frequency range (e.g., 250 to 8000 Hz analysis bandwidth of the probe). One benefit of the WAI method is that the MEMR can be identified in a single test regardless of the frequency at which the maximum shift in the immittance measurement occurs; this is beneficial because maximal shifts in immittance vary as a function of age and other factors. Another benefit is that the wideband response analysis yields lower MEMR thresholds than with the clinical procedures. Lower MEMR thresholds would allow for MEMR decay tests in ears in which the activator levels could not be safely presented. Finally, the WAI procedures can be automated with objective identification of the MEMR, which would allow for use in newborn and other screening programs in which the tests are completed by nonaudiological personnel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-level psychophysical tuning curves: simultaneous masking by pure tones and 100-Hz-wide noise bands.

Simultaneous-masked psychophysical tuning curves were obtained from normal-hearing listeners using low-level (20-25 dB SPL) probe tones in quiet and high-level (60 dB SPL) probe tones, both in quiet and in the presence of a broad-band background noise. The background noise was introduced to eliminate combination tones or combination bands and other off-frequency listening cues that exist at hig...

متن کامل

Using a combination of click- and tone burst-evoked auditory brain stem response measurements to estimate pure-tone thresholds.

DESIGN A retrospective medical record review of evoked potential and audiometric data were used to determine the accuracy with which click-evoked and tone burst-evoked auditory brain stem response (ABR) thresholds predict pure-tone audiometric thresholds. METHODS The medical records were reviewed of a consecutive group of patients who were referred for ABR testing for audiometric purposes ove...

متن کامل

بررسی دقت تخمین آستانه شنوایی بهنجار بوسیله پاسخ‌های برانگیخته قشر شنوایی

Background: Cortical Evoked Response Audiometry (CERA) refers to prediction of behavioral pure-tone thresholds (500-4000 Hz) obtained by recording the N1-P2 complex of auditory long latency responses. CERA is the preferred method for frequency–specific estimation of audiogram in conscious adults and older children. CERA has an increased accuracy of determination of the hearing thresholds of ale...

متن کامل

Wideband reflectance in newborns with present transient-evoked otoacoustic emissions.

PURPOSE To characterize the normal values of acoustic energy reflectance obtained with pure-tone stimulation in neonates prior to hospital discharge. METHODS Seventy-seven infants (37 girls and 40 boys) were evaluated by measuring acoustic reflectance using pure-tone stimuli, transient-evoked otoacoustic emissions, and tympanometric probe frequencies of 226 Hz and 1 kHz. RESULTS At low freq...

متن کامل

The effects of probe-tone frequency on the acoustic-reflex growth function.

Acoustic-reflex growth functions (ARGFs) were obtained from 20 normal-hearing listeners. Contralateral acoustic reflexes (ARs) were elicited with pure tones of 2000 Hz. The magnitude of changes in static compliant susceptance (BA) and conductance (GA) were monitored with probe-tone frequencies of 226 Hz, 678 Hz and 1000 Hz. ARGFs were obtained with six combinations of probe-tone frequency/admit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013