Investigation Non-magnetic Amplifiers Applied in an MRI System
نویسندگان
چکیده
INTRODUCTION: In our previous work on passive current source RF power amplifiers, it was noted that additional inter-element isolation in a parallel transmit coil array was possible when the lengths of the coaxial cables that connected the amplifiers to the coils were reduced [1,2]. In addition, shorter cable lengths also lead to reduced power loss and cost. This can be achieved by placing the RF amplifiers near the magnet (e.g., on front panel or side of the bore) and requires that the amplifiers are compatible within a high magnetic field environment. To accomplish this, the B0 field should have no adverse impact on MOSFET and amplifier behavior, and, the amplifier should also have no notable impact on image quality. In this study, a 1 kW (peak power) non-magnetic amplifier module was designed and constructed. The impact of the B0 field on the non-magnetic amplifier and the effect of non-magnetic amplifier on the performance of the system were investigated on a GE 3T MR750 system (GE Healthcare, Waukesha, WI). The experimental results indicated that, at 3T, the magnetic field had no notable impact on the AC and DC characteristic of the power MOSFET. Similarly, the non-magnetic amplifier had no appreciable impact on B0 and B1 homogeneity, and, image SNR.
منابع مشابه
Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)
Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملAnalytical investigation of the practical range and deflection of megavoltage electron beam in the water phantom with the presence of magnetic field
Introduction: Integrated radiation therapy - MRI systems are capable of delivering high doses to the target tissues near sensitive organs and achieve better therapeutic results; however, the Applied magnetic fields for imaging, can influence the charged path, change the penetration depth and deflect the particles, laterally, leading to dose distribution variations. Therefore, i...
متن کاملMagnetic hyperthermia and MRI relaxometry with dendrimer coated iron oxide nanoparticles
Introduction: Recently, some studies have focused on dendrimer nanopolymers as an MRI contrast agent or a vehicle for gene and drug delivery. Considering the suitable properties of these materials, they are appropriate candidates for coating iron oxide nanoparticles which are applied to magnetic hyperthermia. To the best of our knowledge, the novelty of this study is the inves...
متن کاملApplication of Magnetic Resonance Imaging (MRI) as a safe & Application of Magnetic Resonance Imaging (MRI) as a safe & non-destructive method for monitoring of fruit & vegetable in postharvest period
To investigate and control quality, one must be able to measure quality-related attributes. Quality of produce encompasses sensory attributes, nutritive values, chemical constituents, mechanical properties, functional properties and defects. MRI has great potential for evaluating the quality of fruits and vegetables. The equipment now available is not feasible for routine quality testing. The ...
متن کامل