A randomised clinical trial to investigate bond failure rates using a self-etching primer.

نویسندگان

  • P G Murfitt
  • A N Quick
  • M V Swain
  • G P Herbison
چکیده

This clinical trial evaluated, over a 12-month period, the performance of brackets bonded to teeth etched and primed with Transbond Plus Self-Etching Primer (SEP) when compared with a conventional separate two-step etch and primer system. Thirty-nine randomly selected patients requiring fixed appliance therapy were entered into the study. Random allocation of each etching system, along with a 'split-mouth cross-quadrant' design was used. A total of 661 brackets were placed by two operators. The failure and survival rates of the brackets were determined for age and gender of the patients, each etching system, operator, mode of failure, tooth position in the dental arch, and number of manipulations prior to curing the adhesive. Statistical analysis showed that SEP had a significantly higher bond failure rate (11.2 per cent) than the conventional etch and primer system (3.9 per cent) at the P = 0.001 level. Cox's proportional hazards regression showed the conventional etch and primer system to have a 60 per cent reduced chance of bracket failure over a 12-month observation period, while males had a 2.4 times increased risk compared with females. The predominant mode of failure was at the composite enamel interface for the SEP, while for the conventional etch and primer system, it was within the composite adhesive. No statistically significant differences were found for the failure rate with respect to the age of the patient, operator, tooth location, or the number of manipulations of the bracket. This in vivo study showed that brackets bonded using SEP had an increased clinical bond failure rate compared with the conventional, separate, etch and prime system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Saliva Contamination and sequencing time of curing the Transbond™ Plus Self Etching Primer on the Shear Bond Strength of Orthodontic Brackets

Abstract Background and aim: Over the years, improvments have been done to simplify clinical bonding procedure. One of these material is Transbond™ Plus Self Etching. The aim of this study was to evaluate the effect of saliva contamination and reusing Transbond™ Plus Self Etching Primer (SEP) on shear bond strength of orthodontic brackets. Materials and Methods: Fifty premolars divided into fiv...

متن کامل

An evaluation on the effects of 37% phosphoric acid and self – etching primer on shear bond strength of enamel

An evaluation on the effects of 37% phosphoric acid and self – etching primer on shear bond strength of enamel Dr. A. Davari* - Dr. H. Hajizadeh* - Dr. H. Sharifikhatoonabadi** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry - Yazd University of Medical Sciences. **- Dentist. Background and Aim: The goal of this study was to evaluate the effects of 37% phosphoric acid...

متن کامل

Evaluation of fluoride varnish and its comparison with pumice prophylaxis using self-etching primer in orthodontic bonding--an in vivo study.

The aim of this study was to evaluate the use of fluoride varnish as a prophylaxis method with self etching primer (SEP) and its comparison with pumice before orthodontic bonding. Thirty seven orthodontic patients participated in a prospective clinical trial. A split mouth technique was used in each patient, one quadrant was assigned to fluoride varnish and the contralateral quadrant to pumice ...

متن کامل

Six and 12 months' evaluation of a self-etching primer versus two-stage etch and prime for orthodontic bonding: a randomized clinical trial.

The aim of the study was to compare the mean clinical chair-side time required for bracket bonding and the mean bond failure rate at 6 and 12 months of stainless steel brackets with a micro-etched base bonded with a light-cured composite using a self-etching primer (SEP) or a two-stage etch and prime system.Fifty-one subjects who required upper and/or lower pre-adjusted edgewise fixed appliance...

متن کامل

تأثیر روشهای آماده کردن سطح مینا بر استحکام باند براکت ارتودنسی

Background and Aim: With the introduction of different bondable restorative materials in dentistry, various methods have been suggested to enhance the polymerization and shear bond strength of these materials. The aim of this study was to determine the effects of different methods of enamel conditioning on bond strength of orthodontic brackets and on the bracket/ adhesive failure mode. Material...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 28 5  شماره 

صفحات  -

تاریخ انتشار 2006