Comparison of Image-Based Retrospective and Optical Prospective Motion Correction for Diffusion Tensor Imaging
نویسندگان
چکیده
INTRODUCTION Correction of rigid head motion correction is important in diffusion tensor imaging because of the long acquisition times. Rigid head correction can be carried out either retrospectively prospectively. In this study, we compared the effectiveness of these two approaches in correcting motion artifacts in DTI. Retrospective correction was based on MR-based navigator data (1-3), whilst prospective correction used an external tracking system (4,6).
منابع مشابه
Real-time optical motion correction for diffusion tensor imaging.
Head motion is a fundamental problem in brain MRI. The problem is further compounded in diffusion tensor imaging because of long acquisition times, and the sensitivity of the tensor computation to even small misregistration. To combat motion artifacts in diffusion tensor imaging, a novel real-time prospective motion correction method was introduced using an in-bore monovision system. The system...
متن کاملVolumetric navigators for real-time motion correction in diffusion tensor imaging.
Prospective motion correction methods using an optical system, diffusion-weighted prospective acquisition correction, or a free induction decay navigator have recently been applied to correct for motion in diffusion tensor imaging. These methods have some limitations and drawbacks. This article describes a novel technique using a three-dimensional-echo planar imaging navigator, of which the con...
متن کاملImplementation of Anatomical Navigators for Real Time Motion Correction in Diffusion Tensor Imaging
Thesis: Implementation of Anatomical Navigators for Real Time Motion Correction in Diffusion Tensor Imaging Author‟s Name: Alkathafi A. Alhamud Date: 10-02-2012 Diffusion Tensor Imaging (DTI) is used to detect microstructural changes in the human brain. Although echo planar imaging (EPI) has been implemented in diffusion pulse sequences to minimize the effect of subject motion, motion artifacts...
متن کاملImproved Prospective Optical Motion Correction for DTI Using an Extended-Field-of-View and Self-Encoded Marker
INTRODUCTION – Due to the prolonged acquisition time, correction for rigid-body motion artifacts is essential for diagnostic image quality in DTI. Prospective motion correction using a monovision camera system and a checkerboard marker has previously been used to correct for rigid head motion artifacts [1,2]. In this study, we use a more sophisticated marker design to improve prospective optica...
متن کاملHybrid Prospective & Retrospective Head Motion Correction System to Mitigate Cross-Calibration Errors
INTRODUCTION – Correction of head motion artifacts is essential for clinically acceptable image quality. This is especially important for long scans, such as DTI, fMRI, and high-resolution structural scans. Prospective motion-correction using stereovision systems [1,2] have been suggested to perform real-time head motion-correction without necessitating the acquisition of additional MR-based na...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010