The accuracy of blood pressure measured by arterial line and non-invasive cuff in critically ill children
نویسندگان
چکیده
BACKGROUND The accuracy of arterial lines (AL) using the flush test or stopcock test has not been described in children, nor has the difference between invasive arterial blood pressure (IABP) versus non-invasive cuff (NIBP) blood pressure. METHODS After ethics approval and consent, we performed the flush test and stopcock test on AL (to determine over damping, under damping, and optimal damping), and determined the difference (NIBP-IABP) in systolic, diastolic, and mean blood pressure (ΔSBP, ΔDBP, and ΔMAP). The primary outcome was incidence (95 % CI) of optimally damped AL. Predictors of ΔBP (effect size (95 % CI)) were determined using multiple linear regression. RESULTS There were 147 AL tests in 100 enrolled patients with mean age 44.7 (SD 56) months, weight 16.8 (SD 18.3) kg, male 59 %, postoperative-cardiovascular 52 %, peripheral-AL 78 %, inotropes 29 %, vasodilators 15 %, and ventilated 73 %. The flush test performed in 66 patients (45 %) showed optimal damping in 30 (46 %; 95 % CI 34, 57 %), over damping in 25 (38 %) and under damping in 11 patients (17 %). The stopcock test was over-damped in 128/146 patients (88 %), with the same damping as the flush test in 24/64 (38 %). In optimally damped (flush test) AL, ΔSBP, ΔDBP, and ΔMAP were 0.8 (SD 12.2), -5.2 (SD 8.7), and -4.9 (7.6) respectively. A second set of AL tests was done 2 h later on the same day in 62 patients; AL damping often changed (10/28 flush tests) and ΔBPs correlated poorly (r = 0.31-0.55). Predictors (effect size) of ΔDBP were vasodilator infusion (15.6 (2.9 to 28.3); p = 0.016) and optimal damping (-7.2 (-12.2 to 2.2); p = 0.005); and of ΔMAP were vasodilator infusion (10.0 (-0.3 to 20.4); p = 0.057) and optimal damping (-4.0 (-8 to 0.1); p = 0.058). There were no independent predictors of damping category (n = 66 flush tests). CONCLUSIONS Optimally damped AL occur in half of critically ill children, and this is not predictable. There is much variability in ∆BP between NIBP and the gold standard IABP, and this varies even in the same patient on the same day, and is not easily predictable. In critically ill children, NIBP may not be accurate enough to guide management, and more attention to ensuring the AL is optimally damped is needed.
منابع مشابه
Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملتأثیر بازآموزی ساکشن لوله داخل تراشه برای پرستاران، بر تغییرات فشارخون بیماران بستری در بخش مراقبت ویژه
Background & Aim: Endotracheal suctioning (ETS) is a common invasive nursing procedure. Hemodynamic parameters changes during and after the procedure. If appropriate strategies do not be applied during the ETS, hemodynamic changes can be significant and life threatening in critically ill patients. The purpose of this study was to assess the effect of education of endotracheal suctioning on pati...
متن کاملComparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملDesigning and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals
Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...
متن کامل