Second Law Analysis of a Mobile Air Conditioning System with Internal Heat Exchanger Using Low GWP Refrigerants

نویسندگان

  • Vicente Pérez-García
  • Juan M. Belman-Flores
  • José L. Rodríguez-Muñoz
  • Victor H. Rangel-Hernandez
  • Armando Gallegos-Muñoz
چکیده

This paper investigates the results of a Second Law analysis applied to a mobile air conditioning system (MACs) integrated with an internal heat exchanger (IHX) by considering R152a, R1234yf and R1234ze as low global warming potential (GWP) refrigerants and establishing R134a as baseline. System simulation is performed considering the maximum value of entropy generated in the IHX. The maximum entropy production occurs at an effectiveness of 66% for both R152a and R134a, whereas for the cases of R1234yf and R1234ze occurs at 55%. Sub-cooling and superheating effects are evaluated for each one of the cases. It is also found that the sub-cooling effect shows the greatest impact on the cycle efficiency. The results also show the influence of isentropic efficiency on relative exergy destruction, resulting that the most affected components are the compressor and the condenser for all of the refrigerants studied herein. It is also found that the most efficient operation of the system resulted to be when using the R1234ze refrigerant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Copper-based Heat Exchangers for Alternative Refrigerants

The ongoing global effort to replace current refrigerants with zero Ozone Depletion Potential (ODP) and virtually zero Global Warming Potential (GWP) refrigerants has important implications for heat exchangers, air conditioning system design, and the materials choices in these designs. Natural refrigerants with higher flammability, CO2, HFOs, and HFC – HFO blends each place different requiremen...

متن کامل

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) – Summary of Phase II Testing Results

The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) recently completed the second phase of its Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP). This industry-wide cooperative research program identified and evaluated promising alternative refrigerants over the past five years. Seventeen low-GWP refrigerants were tested during the second phas...

متن کامل

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â•fi Summary of Phase I Testing Results

The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) recently completed the first phase of its low global warming potential alternative refrigerants evaluation program (Low-GWP AREP). This industry-wide cooperative research program identified and evaluated promising alternative refrigerants’ performance over the past two years. Thirty-eight low-GWP refrigerants were tested during t...

متن کامل

امکان‌سنجی استفاده از مبدل بازیاب حرارت در سیکل تبرید تراکمی بخار با آنالیز ترمودینامیکی، انتقال حرارت و اقتصادی

Usually, it is common to use the internal heat exchanger subcooler-superheater after the condenser and before the expansion valve in the compression refrigeration cycles. In this study, the effect of the heat exchanger is evaluated by using recovery heat exchanger after the compressor and before the condenser. To this end, the vapor compression refrigeration cycle with conventional heat exchang...

متن کامل

Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology

The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Entropy

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2017