Direct determination of valproic acid in biological fluids by capillary electrophoresis with contactless conductivity detection.

نویسندگان

  • Gamze Kavran Belin
  • Stephan Krähenbühl
  • Peter C Hauser
چکیده

Capacitively coupled contactless conductivity detection (C(4)D) is a new technique providing high sensitivity in capillary electrophoresis (CE) especially for small ions that can otherwise only be determined with indirect methods. In this work, direct determination and validation of valproic acid (VPA) in biological fluids was achieved using CE with C(4)D. VPA is of pharmacological interest because of its use in epilepsy and bipolar disorder. The running electrolyte solution used consisted of 10mM 2-(N-morpholino)ethane sulfonic acid (MES)/dl-histidine (His) and 50microM hexadecyltrimethylammonium bromide (HTAB) at pH 6.0. Caproic acid (CA) was selected as internal standard (IS). Analyses of VPA in serum, plasma and urine samples were performed in less than 3min. The interference of the sample matrix was reduced by deproteinization of the sample with acetonitrile (ACN). The effect of the solvent type and ratio on interference was investigated. The limits of detection (LOD) and quantitation (LOQ) of VPA in plasma samples were determined as 24 and 80ng/ml, respectively. The method is linear between the 2 and 150microg/ml, covering well the therapeutic range of VPA (50-100microg/ml).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of heavy metal ions by capillary electrophoresis with contactless conductivity detection after field-amplified sample injection.

A method has been developed for determining of heavy metal ions by field-amplified sample injection capillary electrophoresis with contactless conductivity detection. The effects of the 2-N-morpholinoethanesulfonic acid/histidine (MES/His) concentration in the sample matrix, the injection time and organic additives on the enrichment factor were studied. The results showed that MES/His with a lo...

متن کامل

Determination of amino acids by capillary electrophoresis with differential resonant contactless conductivity detector.

The impedance of a capacitively coupled contactless conductivity detector (C(4)D) in capillary electrophoresis (CE) was measured by an impedance analysis method. The influence of solution conductivity and capillary dimension on impedance parameters was investigated. Under the experimental conditions used, 86-99.9% of the total impedance of a C(4)D is composed by its imaginary part from the capi...

متن کامل

Comparison of Potassium and Sodium Content in Diet and Non-Diet Soft Drinks by Using Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection

Capillary electrophoresis (CE) with capacitively coupled contactless conductivity detection (C4D) was used for determination of sodium and potassium concentrations in diet and non-diet soft drinks. Higher sodium concentrations were found in the diet samples due to the utilization of sodium salts of cyclamate and saccharine as sweeteners. The CE-C4D method can be used by food industries and heal...

متن کامل

Sensitive Determination of Metal Ions in Drinking Water by Capillary Electrophoresis Coupled with Contactless Conductivity Detection Using 18-Crown-6 Ether and Hexadecyltrimethylammonium Bromide as Complexing Reagents

A simple, economical, and sensitive capillary electrophoresis (CE) method integrated with capacitively coupled contactless conductivity detection was developed for the determination of metal ions such as K+, Na+, Mg2+, Sr2+, Ca2+ in drinking water. 18-Crown-6 ether and Hexadecyltrimethylammonium Bromide (CTAB) were employed as complexing reagents. The effects of electrolyte additives, citric ac...

متن کامل

Analysis of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection

A new method for the determination of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection (MCE-CCD) was proposed. The effects of various electrophoretic operating parameters on the analysis of arecoline were studied. Under the optimal conditions, arecoline was rapidly separated and detected in 1 min with good linearity over t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

دوره 847 2  شماره 

صفحات  -

تاریخ انتشار 2007