Paper-based microfluidic surface acoustic wave sample delivery and ionization source for rapid and sensitive ambient mass spectrometry.
نویسندگان
چکیده
A surface acoustic wave-based sample delivery and ionization method that requires minimal to no sample pretreatment and that can operate under ambient conditions is described. This miniaturized technology enables real-time, rapid, and high-throughput analysis of trace compounds in complex mixtures, especially high ionic strength and viscous samples that can be challenging for conventional ionization techniques such as electrospray ionization. This technique takes advantage of high order surface acoustic wave (SAW) vibrations that both manipulate small volumes of liquid mixtures containing trace analyte compounds and seamlessly transfers analytes from the liquid sample into gas phase ions for mass spectrometry (MS) analysis. Drugs in human whole blood and plasma and heavy metals in tap water have been successfully detected at nanomolar concentrations by coupling a SAW atomization and ionization device with an inexpensive, paper-based sample delivery system and mass spectrometer. The miniaturized SAW ionization unit requires only a modest operating power of 3 to 4 W and, therefore, provides a viable and efficient ionization platform for the real-time analysis of a wide range of compounds.
منابع مشابه
An ambient detection system for visualization of charged particles generated with ionization methods at atmospheric pressure.
RATIONALE With the current state-of-the-art detection of ions only taking place under vacuum conditions, active pixel detectors that operate under ambient conditions are of particular interest. These detectors are ideally suited to study and characterize the charge distributions generated by ambient ionization sources. METHODS The direct imaging capabilities of the active pixel detector are u...
متن کاملFast surface acoustic wave-matrix-assisted laser desorption ionization mass spectrometry of cell response from islets of Langerhans.
A desire for higher speed and performance in molecular profiling analysis at a reduced cost is driving a trend in miniaturization and simplification of procedures. Here we report the use of a surface acoustic wave (SAW) atomizer for fast sample handling in matrix-assisted laser desorption ionization mass spectrometry (MALDI MS) peptide and protein profiling of Islets of Langerhans, for future t...
متن کاملPlasma-based ambient sampling/ionization/transmission integrated source for mass spectrometry.
Better sensitivity and interface of ambient sampling/ionization mass spectrometry remain a challenge. Herein, a novel, plasma-based, ambient sampling/ionization/transmission (PASIT) integrated source in a pin-to-funnel configuration was developed for the sensitive analysis of complex samples. With the funnel sleeve directly affected by direct-current discharge plasma, PASIT combines the ability...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 83 9 شماره
صفحات -
تاریخ انتشار 2011