Determination of marine gamma activity and study of the minimum detectable activity (MDA) in 4pi geometry based on Monte Carlo simulation.
نویسندگان
چکیده
Monte Carlo simulations were performed using the GEANT4 code for the investigation of gamma-ray absorption in water in different spherical geometries and of the efficiency of a NaI(Tl) detector for different radionuclides in the aquatic environment. In order to test the reliability of these simulations, experimental values of the NaI(Tl) detector efficiency were deduced and seem to be in good agreement with the simulated ones. In addition, using the simulated efficiency, an algorithm was developed to determine the minimum detectable activity in becquerels per cubic meter in situ as a function of energy for typical freshwater and seawater spectra.
منابع مشابه
Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods
High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...
متن کاملDetermination of Radionuclide Concentrations in Tea Samples Cultivated in Guilan Province, Iran
Introduction Foodstuffs are known to contain natural and artificial radionuclides. Determination of radionuclide concentration is of great significance for the protection of human health. The main objective of the present study was the quantification of radionuclides in tea samples, cultivated in Guilan Province in North of Iran. Materials and Methods The activity concentrations of 226Ra, 232Th...
متن کاملOptimization of measurement counting time in Gamma-ray spectrometry of soil samples
The method of optimal measurement counting time in Gamma spectrometry for soil samples was studied. Gamma spectrometry was done based on minimum detectable activity using the HPGe- p type with efficiency of 30% and FWHM 1.7keV (for 1.33 MeV 60Co). The samples were IAEA-RG Th-1, IAEA-RGU-1 and IAEA-RGK-1 prepared in bottles. The measurements were done for 12 different counting times from 5 min t...
متن کاملA Monte Carlo Study on the Shielding Properties of a Novel Polyvinyl Alcohol (PVA)/WO3 Composite, Against Gamma Rays, Using the MCNPX Code
Background: In recent years, there has been an increased interest toward non-lead radiation shields consisting of small-sized filler particles doped into polymer matrices. In this paper, we study a new polyvinyl alcohol (PVA)/WO3 composite in the presence of high-energy gamma photons through simulation via the Monte Carlo N-Particle (MCNP) simulation code. Materia...
متن کاملStudy on effect of detector type in estimating buildup factor of gamma-rays by monte carlo simulation based on variance reduction
This paper presents the study on the effect of detector type in estimating gamma rays buildup factor. In this regard, the flux buildup factors of gamma rays emitted by an isotropic point 60Co source in mean energy 1.253 MeV was evaluated after passing through the Pb, W, Zn, and Ti sample in thickness of 1-5 cm by MCNPX. Four common detector types in simulation of measurement was defined to esti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental monitoring and assessment
دوره 165 1-4 شماره
صفحات -
تاریخ انتشار 2010