Subdiffraction microholograms in a single-photon, uniformly inhibited system

نویسندگان

  • Robert R. McLeod
  • Benjamin A. Kowalski
  • Michael M. Cole
چکیده

Microholograms significantly smaller than the diffraction limit are demonstrated in a photopolymer system with uniformly distributed inhibitor. This subdiffraction performance affords both increased storage density and increased readout signal via suppression of out-of-focus exposure. A model of the micron-scale reaction kinetics of the system is presented, and parameter values are derived experimentally. KeywordsMicroholographic Data Storage, Diffusion Driven Photopolymers, Super-resolution Photolithography

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Near-isotropic 3D optical nanoscopy with photon-limited chromophores.

Imaging approaches based on single molecule localization break the diffraction barrier of conventional fluorescence microscopy, allowing for bioimaging with nanometer resolution. It remains a challenge, however, to precisely localize photon-limited single molecules in 3D. We have developed a new localization-based imaging technique achieving almost isotropic subdiffraction resolution in 3D. A t...

متن کامل

Hydrodynamic Frequency Analysis of a Uniformly Moored SPM in Persian Gulf Environment Using Numerical Method

Single Point Mooring (SPM) are floating Structures that are deployed in deep water which their duties are vessel mooring and transferring oil and gas productions by pipelines from shore to petroleum tankers and conversely. One of the most important components of SPM is mooring system. Which bears not only environmental loads but also petroleum tanker loads which conducted by two thick ropes. Mo...

متن کامل

Single-image far-field subdiffraction limit imaging with axicon.

This Letter presents a technique for subdiffraction limit imaging termed Bessel beam microscopy (BBM). By placing a lens in series with an axicon in the optical path of a microscope, the diffraction-limited resolution of the base microscope is improved by one third. This improvement is demonstrated experimentally by resolving individual subdiffraction limit fluorescent beads in a close-pack arr...

متن کامل

Image Optimization in Single Photon Emission Computed Tomography by Hardware Modifications with Monte Carlo Simulation

Introduction: In Single Photon Emission Computed Tomography (SPECT), the projection data used for image reconstruction are distorted by several factors, including attenuation and scattering of gamma rays, collimator structure, data acquisition method, organ motion, and washout of radiopharmaceuticals. All these make reconstruction of a quantitative SPECT image very difficult. Simulation of a SP...

متن کامل

Coherent Transport of Single Photon in a Quantum Super-cavity with Mirrors Composed of Λ-Type Three-level Atomic Ensembles

In this paper, we study the coherent transport of single photon in a coupled resonator waveguide (CRW) where two threelevel Λ-type atomic ensembles are embedded in two separate cavities. We show that it is possible to control the photon transmission and reflection coefficients by using classical control fields. In particular, we find that the total photon transmission and reflection are achieva...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011