Reliability and Validity of the Chinese Version Appropriateness Evaluation Protocol

نویسندگان

  • Wenwei Liu
  • Suwei Yuan
  • Fengqing Wei
  • Jing Yang
  • Zhe Zhang
  • Changbin Zhu
  • Jin Ma
  • Lamberto Manzoli
چکیده

OBJECTIVE To adapt the Appropriateness Evaluation Protocol (AEP) to the specific settings of health care in China and to validate the Chinese version AEP (C-AEP). METHODS Forward and backward translations were carried out to the original criteria. Twenty experts participated in the consultancy to form a preliminary version of the C-AEP. To ensure applicability, tests of reliability and validity were performed on 350 admissions and 3,226 hospital days of acute myocardial infraction patients and total hip replacement patients in two tertiary hospitals by two C-AEP reviewers and two physician reviewers. Overall agreement, specific agreement, and Cohen's Kappa were calculated to compare the concordance of decisions between pairs of reviewers to test inter-rater reliability and convergent validity. The use of "overrides" and opinions of experts were recorded as measurements of content validity. Face validity was tested through collecting perspectives of nonprofessionals. Sensitivity, specificity, and predictive values were also reported. RESULTS There are 14 admission and 24 days of care criteria in the initial version of C-AEP. Kappa coefficients indicate substantial agreement between reviewers: with regard to inter-rater reliability, Kappa (κ) coefficients are 0.746 (95% confidence interval [CI] 0.644-0.834) and 0.743 (95% CI 0.698-0.767) of admission and hospital days, respectively; for convergent validity, the κ statistics are 0.678 (95% CI 0.567-0.778) and 0.691 (95% CI 0.644-0.717), respectively. Overrides account for less than 2% of all judgments. Content validity and face validity were confirmed by experts and nonprofessionals, respectively. According to the C-AEP reviewers, 18.3% of admissions and 28.5% of inpatient days were deemed inappropriate. CONCLUSIONS The C-AEP is a reliable and valid screening tool in China's tertiary hospitals. The prevalence of inappropriateness is substantial in our research. To reduce inappropriate utilization, further investigation is needed to elucidate the reasons and risk factors for this inappropriateness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Representation of South Asian people in randomised clinical trials: analysis of trials' data.

The study confirmed the reliability and validity of the instrument for the objective evaluation of the appropriateness of surgical bed occupancy in a colorectal unit. A Canadian report on the American appropriateness evaluation protocol showed a poor validity against a panel of experts ( =0.25). A European version of the protocol has been suggested but has not been validated in a substantial st...

متن کامل

Assessing the Validity and Reliability of the Persian Version of the Interpersonal Problem Solving Skills Assessment Tool in Schizophrenia

Objective: This study aimed to translate the Assessment of Interpersonal Problem-Solving Skills (AIPSS) into Persian and to evaluate the validity and reliability of the Persian version of AIPSS to use for adults with schizophrenia. Materials & Methods: In this methodological study, the translation process was performed according to the International Quality of Life Assessment (IQOLA) protocol....

متن کامل

Evaluation of Reliability and Validity of the Hendrich II Fall Risk Model in a Chinese Hospital Population

To translate, validate and examine the reliability and validity of a Chinese version of the Hendrich II Fall risk Model (HFRM) in predicting falls in elderly inpatient. A sample of 989 Chinese elderly inpatients was recruited upon admission at the Peking Union Medical College Hospital. The inpatients were assessed for fall risk using the Chinese version of the HFRM at admission. The reliability...

متن کامل

Psychometric Properties of the Chinese Shortened Version of the Zuckerman–Kuhlman Personality Questionnaire in a Sample of Adolescents and Young Adults

Introduction: The original 89-item Zuckerman-Kuhlman Personality Questionnaire (form III Revised, ZKPQ-III-R) is a widely accepted and used self-report measure for personality traits. This study assessed the reliability and construct validity of the Chinese short 46-item version of the ZKPQ-III-R in a sample of adolescents and young adults. Methodology: A total of 1,019 Chinese adolescents and ...

متن کامل

Who should be admitted to hospital? Evaluation of a screening tool.

OBJECTIVE To develop a tool for evaluating the appropriateness of acute hospital admissions in Hong Kong and test its reliability. DESIGN The tool was based on the Appropriateness Evaluation Protocol and consensus of local Emergency Medicine specialists. Reliability was tested through retrospective chart review. SETTING Tertiary teaching hospital, Hong Kong. PATIENTS Seventy-five randomly...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015