Polyethylene Bearing Stress Fractures after Mobile-bearing Cruciate-retaining Total Knee Arthroplasty: Case Reports

نویسنده

  • Jong Keun Seon
چکیده

Some reported bearing fractures are due to entrapment of the bearing between the femoral component and posterior edge of the tibial base plate in unstable meniscal –bearing design TKA. However, so far no cases of bearing fracture has been reported for the rotating platform or anteroposterior gliding designs of mobile bearing TKA. The authors describe two cases of polyethylene stress fracture after primary TKA using a cruciate-retaining floating platform mobile-bearing prosthesis (e.motion-FP, B.Braun-Aesculap, Tuttlingen, Germany), and includes a review of the pertinent literature and a discussion of possible fracture mechanisms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Traumatic Dislodgement of Tibial Polyethylene Insert after a High-Flex Posterior-Stabilized Total Knee Replacement

Many pathologic entities can produce a painful total knee replacement (TKR) that may lead to potential prosthetic failure. Polyethylene insert dissociation from the tibial baseplate has been described most frequently after mobile-bearing and cruciate-retaining TKRs. However, only 3 tibial insert dislocations in primary fixed-bearing High-Flex posterior-stabilized TKRs have been reported. We pre...

متن کامل

Posterior cruciate-retaining, rotating-platform total knee arthroplasty: minimum 4-year follow-up study.

Rotating-platform, mobile-bearing total knee arthroplasty was initially developed using a posterior cruciate-sacrificing technique and design. Posterior cruciate-substituting and -retaining, rotating-platform total knee arthroplasty designs were developed later. The purpose of this study was to evaluate a minimum 4-year follow-up of total knee arthroplasty performed with a posterior cruciate-re...

متن کامل

Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint

BACKGROUND The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty.No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA).Therefore, the...

متن کامل

Dissociation of mobile-bearing patellar component in low contact stress patellofemoral arthroplasty, its mechanism and management: two case reports

INTRODUCTION Isolated patellofemoral osteoarthritis can be treated with patellofemoral arthroplasty. CASE PRESENTATION We present two cases of isolated patellofemoral osteoarthritis treated with Low Contact Stress patellofemoral arthroplasty; in both cases the polyethylene mobile-bearing of the patellar component dissociated from the metal backing. One patient had a revision to a Richards pat...

متن کامل

Analysis and Treatment of Complications after Unicompartmental Knee Arthroplasty

PURPOSE To analyze the causes and types of complications after unicompartmental knee arthroplasty (UKA) and determine proper prevention and treatment methods. MATERIALS AND METHODS A total of 1,576 UKAs were performed for osteoarthritis of the knee from January 2002 to December 2014 at one institution. We analyzed complications after UKA retrospectively and investigated proper methods of trea...