Improved susceptibility weighted imaging method using multi-echo acquisition.
نویسندگان
چکیده
PURPOSE To introduce novel acquisition and postprocessing approaches for susceptibility weighted imaging (SWI) to remove background field inhomogeneity artifacts in both magnitude and phase data. METHODS The proposed method acquires three echoes in a three-dimensional gradient echo (GRE) sequence, with a field compensation gradient (z-shim gradient) applied to the third echo. The artifacts in the magnitude data are compensated by signal estimation from all three echoes. The artifacts in phase signals are removed by modeling the background phase distortions using Gaussians. The method was applied in vivo and compared with conventional SWI. RESULTS The method successfully compensates for background field inhomogeneity artifacts in magnitude and phase images, and demonstrated improved SWI images. In particular, vessels in frontal lobe, which were not observed in conventional SWI, were identified in the proposed method. CONCLUSION The new method improves image quality in SWI by restoring signal in the frontal and temporal regions.
منابع مشابه
Rapid multi-orientation quantitative susceptibility mapping
Three-dimensional gradient echo (GRE) is the main workhorse sequence used for susceptibility weighted imaging (SWI), quantitative susceptibility mapping (QSM), and susceptibility tensor imaging (STI). Achieving optimal phase signal-to-noise ratio requires late echo times, thus necessitating a long repetition time (TR). Combined with the large encoding burden of whole-brain coverage with high re...
متن کاملImprovement of the SNR and resolution of susceptibility-weighted venography by model-based multi-echo denoising
The vein structures of the brain are important for understanding brain function and structure, especially when functional magnetic resonance imaging (fMRI) is utilized, as fMRI is based on changes in the blood-oxygen-level-dependent (BOLD) signal, which is directly related to veins. The aim of the present study was to develop an effective method to produce high signal-to-noise-ratio (SNR) and h...
متن کاملHigh Spatiotemporal Resolution Whole Brain Susceptibility Weighted Imaging Using Parallel Imaging
Introduction: Susceptibility-weighted imaging (SWI) is a newly developed approach to enhance contrast between tissues with different magnetic susceptibilities [1]. SWI takes advantage of the high sensitivity of NMR phase images to tissue susceptibility differences, and enhances image contrast in magnitude images using NMR phase images as masks. In addition to its initial application for imaging...
متن کاملHigh-resolution, Anatomically-accurate Diffusion-weighted Imaging of Orbital and Sinonasal Lesions with RESOLVE
Diffusion-weighted imaging is a core sequence in clinical routine imaging for many anatomical regions including the brain, abdomen, breasts, and pelvis [1, 2]. Conventionally, diffusion-weighted imaging is acquired using a single-shot diffusion-weighted echo planar imaging (EPI) sequence with the primary advantages of insensitivity to motion-induced phase errors and relatively short acquisition...
متن کاملSingle Echo Simultaneous Angiography and Venography (MRAV) Techniques at 3T
Introduction: Several techniques have been presented in the last year to acquire both angiographic and venographic information in a single acquisition (MRAV) using susceptibility weighted imaging (SWI). However, these techniques either require a double echo acquisition (1) or a single echo with flip angles that tend to compromise the quality of either the angiography or venography (2). In this ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 72 2 شماره
صفحات -
تاریخ انتشار 2014