Selection of a battery of rapid toxicity sensors for drinking water evaluation.

نویسندگان

  • William H van der Schalie
  • Ryan R James
  • Thomas P Gargan
چکیده

Comprehensive identification of chemical contaminants in Army field water supplies can be a lengthy process, but rapid analytical methods suitable for field use are limited. A complementary approach is to directly measure toxicity instead of individual chemical constituents. Ten toxicity sensors utilizing enzymes, bacteria, or vertebrate cells were tested to determine the minimum number of sensors that could rapidly identify toxicity in water samples containing one of 12 industrial chemicals. The ideal sensor would respond at a concentration just exceeding the Military Exposure Guideline (MEG) level for the chemical (an estimated threshold for adverse effects) but below the human lethal concentration. Chemical solutions were provided to testing laboratories as blind samples. No sensors responded to deionized water blanks, and only one sensor responded to a hard water blank. No single toxicity sensor responded to more than six chemicals in the desired response range, and one chemical (nicotine) was not detected by any sensor with the desired sensitivity. A combination of three sensors (Microtox, the Electric Cell Substrate Impedance Sensing (ECIS) test, and the Hepatocyte low density lipoprotein (LDL) uptake test) responded appropriately to nine of twelve chemicals. Adding a fourth sensor (neuronal microelectrode array) to the test battery allowed detection of two additional chemicals (aldicarb and methamidophos), but the neuronal microelectrode array was overly sensitive to paraquat. Evaluating sensor performance using a standard set of chemicals and a desired sensitivity range provides a basis both for selecting among available toxicity sensors and for evaluating emerging sensor technologies. Recommendations for future toxicity sensor evaluations are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity.

This manuscript describes how to prepare fluidic biochips with Rainbow trout gill epithelial (RTgill-W1) cells for use in a field portable water toxicity sensor. A monolayer of RTgill-W1 cells forms on the sensing electrodes enclosed within the biochips. The biochips are then used for testing in a field portable electric cell-substrate impedance sensing (ECIS) device designed for rapid toxicity...

متن کامل

Rapid detection of the most important pathogenic microorganisms in water and Food by (Chromogenic media)

Abstract Background and Objectives: Chromogenic media are the newest methods applied for rapid detection of pathogenic microorganisms in drinking water and food from 1998-2008. These Specific media contained the compounds acting as a substrate for microbial enzymes and, according to the type of enzyme, produce specific color. The aim of this study was to introduce the chromogenic media as a pow...

متن کامل

Lifetime risk assessment of Radium-226 in drinking water samples

Background: One of the most significant radionuclides in natural drinking waters is 226Ra and its decay products. It is potential of health problems, including cancer risk. In this study, the effect of 226Ra concentration in 28 drinking water samples collected from the North Guilan province was investigated. Materials and Methods: The activity concentrations of 226Ra were measured by using of r...

متن کامل

Evaluation of Knowledge and Attitude of Kerman Residents about the Usage of Bottled Water for Drinking and Cooking Purposes

Use of bottled water for drinking and cooking purposes is common in many communities, particulary in places where there is no water of good quality. This type of water supply is an appropriate alternative in prevention of much investment in full- scaled water treatment and duall water distribution system. In Iran, where water is considered as a serious challenge, use of bottled water can be con...

متن کامل

Performance Evaluation of Point-Of-Use Drinking Water Treatment Units in Removal of Heavy Metals and Dissolved Solids from Drinking Water Supply in Tabriz

Introduction: Application of point-of-use (POU) drinking water treatment units is expanding across the world due to the increased concerns about the adverse health effects of water pollution. The main treatment systems of these devices are mostly activated carbon and nano-filter or reverse osmosis. Materials and Methods: This study was conducted to evaluate the effect of using POU units on phy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2006