Stability of 35-mm scanners as used in ophthalmologic research.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVE To assess the consistency of digitization of 35-mm slides as practiced in ophthalmologic research and estimate the impact of variation on semi-automated retinal vessel width measurements. PATIENTS AND METHODS A single retina slide was repeatedly digitized under various conditions on three scanner models. Average color levels were extracted from the resulting images, from which vessel widths were graded. The color channel level variations and possible correlation with width were analyzed. RESULTS The Nikon 5000 scanner (Nikon Corp., Tokyo, Japan) had average coefficients of variation of 0.4, 2.3, and 0.5 for the red, green, and blue channel levels across all runs. The P values of the correlation between the red, green, and blue color channel levels and the width of the large retinal arteriole were .89, .27, and .58, respectively. CONCLUSION The results suggest that the tested scanners digitize the 35-mm slides in a reliable manner without biasing the retinal vessel measurements.
منابع مشابه
Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners
Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...
متن کاملCalculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurement
Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter...
متن کاملComparison of 6 PET scanners, a simulation study [Persian]
Introduction: Due to the large number of PET systems available in the market, it is not very easy to decide about the scanner of choice. Conducting a research in order to compare all different PET scanners is very time consuming and expensive and practically impossible. However, such comparison may be conducted using PET simulators. In this study, the performance of 6 different PET scanne...
متن کاملStudy of PET scanner designs using clinical metrics to optimize the scanner axial FOV and crystal thickness.
The aim of this study is to understand the trade-off between crystal thickness and scanner axial field-of-view FOV (AFOV) for clinical PET imaging. Clinical scanner design has evolved towards 20-25 mm thick crystals and 16-22 cm long scanner AFOV, as well as time-of-flight (TOF) imaging. While Monte Carlo studies demonstrate that longer AFOV and thicker crystals will lead to higher scanner sens...
متن کاملOptimization of Anti-Rh D Immunoglobulin Stability in the Lyophilization Processes
Objective Anti-Rh D IgG is used for the prevention of anti-D antibody production in Rh- individuals who have been exposed to Rh+ red blood cells. The stability of IgG preparations as a solution is low, with a shelf life of a year or more. Formulation of anti-Rh D IgG as a lyophilized preparation would decrease its degradation rate and increases its shelf life. The objective of this study was t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye
دوره 41 1 شماره
صفحات -
تاریخ انتشار 2010