The Genesis of Gallop Sounds: Investigation
نویسندگان
چکیده
The genesis of gallop sounds was investigated in 12 patients by simultaneous measurement of external apexcardiographic (ACG) and left ventricular (LV) pressure, dP/dt, and sound using infinite time constant piezo-resistive pressure transducers with identical sensitivity and frequency responses. Absolute intensity of internal and external sound was quantified. The external transducer was applied to the chest wall with a pressure of 200-400 mm Hg. Six patients had a third heart sound (S,), eight had a fourth heart sound (S4) and
منابع مشابه
Investigation of genesis of gallop sounds in dogs by quantitative phonocardiography and digital frequency analysis.
Several investigators have noted external gallop sounds to be of higher amplitude than their corresponding internal sounds (S3 and S4). In this study we hoped to determine if S3 and S4 are transmitted in the same manner as S1. In 11 closed-chest dogs, external (apical) and left ventricular pressures and sounds were recorded simultaneously with transducers with identical sensitivity and frequenc...
متن کاملInvestigation of genesis of gallop sounds in dogs by quantitative phonocardiography and digital frequency analysis ANDRE
Several investigators have noted external gallop sounds to be of higher amplitude than their corresponding internal sounds (S3 and S4). In this study we hoped to determine if S3 and S4 are transmitted in the same manner as S,. In 11 closed-chest dogs, external (apical) and left ventricular pressures and sounds were recorded simultaneously with transducers with identical sensitivity and frequenc...
متن کاملThe genesis of the third and fourth heart sounds. A pressure-flow study in dogs.
To examine the mechanism of mitral flow deceleration in diastole and its potential influence on the genesis of third (S3) and fourth (S4) heart sounds, we simultaneously recorded left atrial and left ventricular pressures (micromanometers), mitral flow velocity (electromagnetic catheter-tip flow velocity meter), and internal and external phonocardiograms in 25 open-chest dogs. Diastolic time in...
متن کاملExperimental gallop rhythm in sheep with Gousiekte: correlation of changes in amplitude with haemodynamic parameters.
To investigate the correlation of haemodynamic parameters with the intensity of the gallop sound (S3), use was made of right heart catheterization with a Swan-Ganz catheter to measure the pulmonary and right atrial pressures. The cardiac output was determined with the thermodilution method. A radiocardiogram was obtained after a bolus injection of technetium pertechnetate. The cardiopulmonary f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005