Ergonomic Evaluation of upper limb movements in the automobile production measured by means of motion capturing

نویسندگان

  • Christin Hölzel
  • CHRISTIN HÖLZEL
چکیده

Concerning that many production tasks are still mainly manual, examining typical workloads at production sites is a challenging task. Currently, workspace design is evaluated by experts, filling ergonomic evaluation sheets by estimation of postures and loads. The use of motion capture systems could improve the evaluation process of body postures to achieve accurate data and detailed results on working postures. With regard to the automotive industry motion capturing should be used to analyze movements while performing assembly line tasks, to identify critical postures and to reduce risks of upper limb disorders due to suggesting enhancements of working stations as well as working tasks. This study compares the use of two different motion capture systems (one optical based system: Vicon Nexus; one inertial based system: MyoMotion Noraxon) for the automotive production. 11 participants inserted two fuel pipes and six plugs of different sizes at a selected workplace which was part of the pivot assembly line at an automotive OEM. The results of Vicon and Noraxon were implemented in an ergonomic assessment worksheet to identify critical postures of the upper limb throughout the entire working cycle. Systems were compared due to the results out of the ergonomic evaluation. Furthermore results of the wrist joint angles, calculated with the MyoMotion system, and typical plug insertion forces, measured with a load cell, are presented. Results of Vicon and Noraxon do not differ significant for the summed up value of the ergonomic evaluation. No strain of the neck is identified for the selected tasks. Percentage of work above shoulder height differs between 43 -70% for Vicon and 55-75% for Noraxon between participants. Reasons for intra-individual differences might be due to sensor attachment as well as natural variability of movements. Joint angles of the wrist exceed critical ranges of movement during some tasks, but for the plug insertion no exceeding of critical ranges was examined. Nevertheless plug insertion proved to produce muscular strains due to the high measured forces.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Real-time Motion Tracking Wireless System for Upper Limb Exosuit Based on Inertial Measurement Units and Flex Sensors (TECHNICAL NOTE)

This paper puts forward a real-time angular tracking (motion capture) system for a low cost upper limb exosuit based on sensor fusion; which is integrated by an elastic sleeve-mitten, two inertial measurement units (IMU), two flex sensors and a wireless communication system. The device can accurately detect the angular position of the shoulder (flexion-extension, abduction-adduction and interna...

متن کامل

Ergonomic Assessment of Musculoskeletal Disorders Risk by Rapid Upper Limb Assessment (RULA) Technique in a PorcelainManufacturing Factory.

Abstract: Introduction: Musculoskeletal disorders have been devoted high percentage of occupational injuries and it is one of the leading causes of absence from work and disability. In this study we aimed to determine prevalence of musculoskeletal disorders and their risk factors and to evaluate exposure of musculoskeletal disorders risk factors by Rapid Upper Limb Assessment (RULA) Technique...

متن کامل

Comparing strength and range of motion of the upper limb with AV fistula access with the contralateral upper limb among patients treated with hemodialysis

Introduction: The arteriovenous (AV) fistula is a gold standard method for safe and effective repeated vascular access for patients on hemodialysis (HD). The patients, with AV-fistula access in their upper limb, have some limitations in using the involved limb both in daily living and during the dialysis process. The aim of this study was to compare range of motion (ROM), muscle strength and...

متن کامل

Effect of Time Constraind Induced Therapy on Function, Coordination and Movements of Upper Limb on Hemiplegic Adults

Objectives: Stroke, is one of the major causes of disability in adults. So, the patient may prefer to use the non-involved limb to perfom selfcare & named this phenomen learned non used. Constraint induced therapy is one of the rehabilitative interventions that can be effective in restoration of the function of the involved limb in some hemiparetic post stroke patients. purpose of this study wa...

متن کامل

ارزیابی ارگونومیک محیط کار در مراکز ساخت اعضای مصنوعی و وسایل کمکی

  Introduction: In the orthotic and prosthetic workshops, awkward postures, repetitive and continuously movements etc. are the risk factors of musculoskeletal disorders (MSDs). This study was conducted with the objective of ergonomic assessment of working conditions in these workshops. Material and Methods: In this study all employed personnel of linorthotic and prosthetic product...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014