Off-line sampling of exhaled air for nitric oxide measurement in children: methodological aspects.
نویسندگان
چکیده
Measurement of nitric oxide in exhaled air is a noninvasive method to assess airway inflammation in asthma. This study was undertaken to establish the reference range of exhaled NO in healthy school-aged children and to determine the influence of ambient NO, noseclip and breath-holding on exhaled NO, using an off-line balloon sampling method. All children attending a primary school (age range 8-13 yrs) underwent NO measurements on two occasions with high and low ambient NO. Each time, the children performed four expiratory manoeuvres into NO-impermeable balloons, with and without 10 s of breath-holding and with and without wearing a noseclip. Exhalation flow and pressure were not controlled. NO was measured within 4 h after collection, by means of chemiluminescence. All children completed a questionnaire on respiratory and allergic disorders, and performed flow/volume spirometry. With low ambient NO, the mean exhaled NO value of 72 healthy children with negative questionnaires and normal lung function was 5.1 +/- 0.2 parts per billion (ppb) versus a mean of 6.8 +/- 0.3 ppb in the remaining 49 children with positive questionnaires for asthma and allergy, and/or recent symptoms of cold (p=0.001). Exhaled and ambient NO were significantly related, especially with ambient NO > 10 ppb (r = 0.86, p=0.0001 versus r=0.34, p=0.004 for ambient values <10 ppb). The use of a noseclip, with low ambient NO and without breath-holding, caused a small decrease in exhaled NO values (p=0.001). The effect of breath-holding on exhaled NO depended on ambient NO. With ambient NO > 10 ppb, exhaled NO decreased, whereas with ambient NO < 10 ppb, exhaled NO increased after 10 s breath-hold. It is concluded that off-line sampling in balloons is a simple and, hence, attractive method for exhaled nitric oxide measurements in children which differentiates between groups with and without self-reported asthma, allergy and colds, when ambient nitric oxide is < 10 parts per billion. Wearing a noseclip and breath-holding affected measured values and should, therefore be standardized or, preferably, avoided.
منابع مشابه
Exhaled nitric oxide measurements with dynamic flow restriction in children aged 4-8 yrs.
Fractional exhaled nitric oxide concentration (FENO) depends on exhalation flow; however, children often are unable to perform controlled flow procedures. Therefore, a device was developed for off-line FENO sampling, with dynamic flow restriction (DFR). The authors compared off-line with on-line FENO, assessed feasibility, and obtained normal values for FENO in children aged 4-8 yrs. Subjects i...
متن کاملControlled low flow oV line sampling of exhaled nitric oxide in children
Background—The aim of this study was to validate exhaled nitric oxide (eNO) values obtained with an alternative oV line, single breath, low flow balloon sampling method against on line sampling according to ERS and ATS guidelines in children who could perform both methods. Methods—One hundred and twenty seven white children of median age 14.1 years, all pupils of a secondary school, participate...
متن کاملA new method for the remote collection of nasal and exhaled nitric oxide.
STUDY OBJECTIVES The present study introduces a method that has been developed to improve the remote collection and transportation of gas samples from the nose and lungs. DESIGN Assessment of agreement between two methods of clinical measurements. SETTING Noninvasive exhaled gas measurement at a respiratory research laboratory. PARTICIPANTS Ten nonsmoking adult volunteers (median age, 44 ...
متن کاملMeasurement of exhaled nitric oxide in children, 2001.
Measurement of fractional exhaled nitric oxide in exhaled air is an exciting innovative technique that gives new insights in to the pathophysiology of lung disease and asthma in particular, with many potential clinical applications. Careful standardisation of measurement techniques will facilitate the use of this new measurement in paediatric respiratory medicine: this Task Force was set up for...
متن کاملComparison of single-breath and tidal breathing exhaled nitric oxide levels in infants.
The aim of this study was to compare two different methods, tidal breathing (TB) and single-breath (SB), for measuring fractional exhaled nitric oxide (FENO) in infants. FENO was measured in 71 infants with either recurrent wheeze (n=32), recurrent cough (n=16) or no symptoms (healthy, n=23) using both methods. For TB measurements five breaths were collected into a gas sampling bag (off-line re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 17 5 شماره
صفحات -
تاریخ انتشار 2001