Validation by isoelectric focusing of the anion-exchange isotransferrin fractionation step involved in determination of carbohydrate-deficient transferrin by the CDTect assay.

نویسندگان

  • T Arndt
  • R Hackler
  • T O Kleine
  • A M Gressner
چکیده

Serum concentration of carbohydrate-deficient transferrin (CDT) is used for laboratory diagnosis of chronic alcohol abuse. Using isoelectric focusing for validation of the initial isotransferrin fractionation step involved in the determination of CDT by the CDTect assay, we found a complete in vitro iron saturation of transferrin and sufficient stability of the transferrin iron load during column passage; effective separation of non-CDT-isotransferrins and CDT-isotransferrins at the microcolumns; partial coelution of trisialo-Fe2-transferrin, which did not significantly affect CDT measurement; partial retention of CDT-isotransferrins, especially disialo-Fe2-transferrin, which may cause falsely negative results for CDT at the upper reference limits; good precision of the isotransferrin fractionation step; and no significant effects of low concentrations of serum protein and transferrin. We strongly urge standardization of CDT analysis and suggest isoelectric focusing for validation of CDT analysis methods and verification of odd results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation by isoelectric focusing of the initial carbohydrate-deficient transferrin (CDT) and non-CDT transferrin isoform fractionation step involved in determination of CDT by the ChronAlcoI.D. assay.

BACKGROUND The introduction of a new set of reagents for the determination of carbohydrate-deficient transferrin (CDT) as a marker of chronic alcohol abuse requires an independent evaluation of the analytic specificity of the test. This information is needed for correct interpretation and classification of test results. METHODS Isoelectric focusing on the PhastSystem(TM) followed by immunofix...

متن کامل

Interference of transferrin isoform types with carbohydrate-deficient transferrin quantification in the identification of alcohol abuse.

BACKGROUND Isoforms of transferrin interfere with measurement of carbohydrate-deficient transferrin (CDT) as a marker of heavy alcohol consumption. We evaluated the rate of inaccurate CDT results by immunoassays. METHODS We studied 2360 consecutive sera (1614 individuals) submitted for CDT assay without clinical information as well as samples from 1 patient with a congenital disorder of glyco...

متن کامل

Comparison of HPLC and small column (CDTect) methods for disialotransferrin.

BACKGROUND Current methods for determination of carbohydrate-deficient transferrin (CDT) are based on separation of the CDT fraction by ion-exchange chromatography on minicolumns and quantification by immunoassay. Alternatively, the transferrin isoforms can be separated by HPLC anion-exchange chromatography and quantified by absorbance. This method has been reported to improve the validity of C...

متن کامل

Carbohydrate-deficient transferrin measured by high-performance liquid chromatography and CDTect immunoassay.

Carbohydrate-deficient transferrin (CDT) was measured in three populations using anion-exchange chromatography followed by radioimmunoassay (CDTectTM) and a new high-performance liquid chromatography (HPLC) method. The correlation between the methods in 50 consecutive clinical samples was good (r = 0.87). However, in a set of 49 samples with CDT concentrations close to the reference value of th...

متن کامل

Nephelometric determination of carbohydrate deficient transferrin.

We describe a technique for measuring carbohydrate-deficient transferrin (CDT) in serum. Serum transferrin fractions are separated by anion-exchange chromatography on microcolumns. Sialic acid-deficient transferrin fractions are collected in the eluate, and transferrin is then quantified by a rate-nephelometric technique. Imprecision (CV) was 4-5% within-run and 7-9% between runs (n = 15). Comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 1  شماره 

صفحات  -

تاریخ انتشار 1998