Intra- and Postoperative Electrocochleography May Be Predictive of Final Electrode Position and Postoperative Hearing Preservation
نویسندگان
چکیده
Introduction: The objectives of the current study were to (1) determine the relationship between electrocochleography (ECochG), measured from the cochlear implant (CI) electrode array during and after implantation, and postoperative audiometric thresholds, (2) determine the relationship between ECochG amplitude and electrode scalar location determined by computerized tomography (CT); and (3) determine whether changes in cochlear microphonic (CM) amplitude during electrode insertion were associated with postoperative hearing. Materials and Methods: Eighteen subjects undergoing CI with an Advanced Bionics Mid-Scala device were prospectively studied. ECochG responses were recorded using the implant coupled to a custom signal recording unit. ECochG amplitude collected intraoperatively concurrent with CI insertion and at activation was compared with audiometric thresholds postoperatively. Sixteen patients also underwent postoperative CT to determine scalar location and the relationship to ECochG measures and residual hearing. Results: Mean low-frequency pure tone average (LFPTA) increased following surgery by an average of 28 dB (range 8-50). Threshold elevation was significantly greater for electrodes with scalar dislocation. No correlation was found between intraoperative ECochG and postoperative behavioral thresholds collapsed across frequency; however, mean differences in thresholds measured by intraoperative ECochG and postoperative audiometry were significantly smaller for electrodes inserted completely within scala tympani (ST) vs. those translocating from ST to scala vestibuli. A significant correlation was observed between postoperative ECochG thresholds and behavioral thresholds obtained at activation. Discussion: Postoperative audiometry currently serves as a marker for intracochlear trauma though thresholds are not obtained until device activation or later. When measured at the same time-point postoperatively, low-frequency ECochG thresholds correlated with behavioral thresholds. Intraoperative ECochG thresholds, however, did not correlate significantly with postoperative behavioral thresholds suggesting that changes in cochlear physiology occur between electrode insertion and activation. ECochG may hold clinical utility providing surgeons with feedback regarding insertion trauma due to scalar translocation, which may be predictive of postoperative hearing preservation. Conclusion: CI insertion trauma is generally not evident until postoperative audiometry when loss of residual hearing is confirmed. ECochG has potential to provide estimates of trauma during insertion as well as reliable information regarding degree of hearing preservation.
منابع مشابه
Correlation of Electrophysiological Properties and Hearing Preservation in Cochlear Implant Patients.
OBJECTIVE To monitor changes in cochlear function during cochlear implantation using electrocochleography (ECoG) and to correlate changes to postoperative hearing preservation. METHODS ECoG responses to acoustic stimuli of 250, 500, and 1000 Hz were recorded during cochlear implantation. The recording electrode was placed on the promontory and stabilized to fix the position during cochlear im...
متن کاملRound window electrocochleography before and after cochlear implant electrode insertion.
OBJECTIVE/HYPOTHESIS Previous reports have documented the feasibility of utilizing electrocochleographic (ECoG) responses to acoustic signals to assess trauma caused during cochlear implantation. The hypothesis is that intraoperative round window ECoG before and after electrode insertion will help predict postoperative hearing preservation outcomes in cochlear implant recipients. STUDY DESIGN...
متن کاملAssessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography
Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods: Extra- and intracochlear electrocochleography (ECoG) were used to detect electrophysiological chan...
متن کاملAssessment of Cochlear Trauma During Cochlear Implantation Using Electrocochleography and Cone Beam Computed Tomography.
OBJECTIVE To assess cochlear trauma during cochlear implantation by electrocochleography (ECoG) and cone beam computed tomography (CBCT) and to correlate intraoperative cochlear trauma with postoperative loss of residual hearing. METHODS ECoG recordings to tone bursts at 250, 500, 750, and 1000 Hz and click stimuli were recorded before and after insertion of the cochlear implant electrode arr...
متن کاملExtra- and Intracochlear Electrocochleography in Cochlear Implant Recipients.
OBJECTIVE To monitor cochlear function by extra- and intra-cochlear electrocochleography (ECoG) during and after cochlear implantation and thereby to enhance the understanding of changes in cochlear function following cochlear implantation surgery. METHODS ECoG responses to acoustic stimuli of 250, 500 and 1,000 Hz were recorded in 9 cochlear implant recipients with presurgical residual heari...
متن کامل