Enhanced permanganate chemiluminescence.
نویسندگان
چکیده
The significant enhancement of acidic potassium permanganate chemiluminescence by Mn(II) results from the concomitant presence of permanganate and Mn(III) in the reagent solution, which enables rapid production of the excited Mn(II) emitter with a wide range of analytes. Furthermore, the key Mn(III) co-reactant can be quickly generated by reducing permanganate with sodium thiosulfate, instead of the slow (~24 h) equilibration required when Mn(ii) is used. The emission from reactions with analytes such as tyrosine and fenoterol was over two orders of magnitude more intense than with the traditional permanganate reagent.
منابع مشابه
Direct Chemiluminescence Determination of Oxymorphone Using Potassium Permanganate and Polyphosphoric Acid
Abstract A simple and sensitive chemiluminescence (CL) method was developed for direct quantification of oxymorphone, a µ opioid agonist that is approximately 10 times more potent than morphine. In this method potassium permanganate in polyphosphoric acid was used as CL reagent. Using this method, oxymorphone can be determined over the concentration ranges 13.5-337.8 ng mL-1 and 0.34-6.76...
متن کاملEffect of oxidant type on the chemiluminescence intensity from the reaction of tris(2,2'-bipyridyl)ruthenium(III) with various organic acids.
An investigation into the chemiluminescence of fourteen organic acids and tris(2,2'-bipyridyl)ruthenium(II) was undertaken. Particular emphasis was placed upon the method of production of the reagent, tris(2,2'-bipyridyl)ruthenium(III), with cerium(IV) sulfate, potassium permanganate, lead dioxide and electrochemical generation. Analytically useful chemiluminescence was observed when Ce(IV) or ...
متن کاملEnhancing permanganate chemiluminescence detection for the determination of glutathione and glutathione disulfide in biological matrices.
Acidic potassium permanganate chemiluminescence enables direct post-column detection of glutathione, but its application to assess the redox state of a wider range of biological fluids and tissues is limited by its sensitivity. Herein we show that the simple on-line addition of an aqueous formaldehyde solution not only enhances the sensitivity of the procedure by two orders of magnitude, but al...
متن کاملPermanganate-based chemiluminescence analysis of ferulic acid using flow injection.
A simple, sensitive and rapid flow-injection chemiluminescence method has been developed for the determination of ferulic acid based on the chemiluminescence reaction of ferulic acid with potassium permanganate in a nitric acid medium. A strong chemiluminescence signal was observed when ferulic acid was injected into an acidic potassium permanganate solution in a flow-cell. The present method a...
متن کاملMolecularly imprinted solid-phase extraction and flow-injection chemiluminescence for trace analysis of 2,4-dichlorophenol in water samples.
Highly sensitive flow-injection chemiluminescence (CL) combined with molecularly imprinted solid-phase extraction (MISPE) has been used for determination of 2,4-dichlorophenol (2,4-DCP) in water samples. The molecularly imprinted polymer (MIP) for 2,4-DCP was prepared by non-covalent molecular imprinting methods, using 4-vinylpyridine (4-VP) and ethylene glycol dimethacrylate (EGDMA) as the mon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 136 1 شماره
صفحات -
تاریخ انتشار 2011