Deposition and dispersion of 1-μm aerosol boluses in the human lung: effect of micro- and hypergravity

نویسنده

  • CHANTAL DARQUENNE
چکیده

Darquenne, Chantal, John B. West, and G. Kim Prisk. Deposition and dispersion of 1-μm aerosol boluses in the human lung: effect of microand hypergravity. J. Appl. Physiol. 85(4): 1252–1259, 1998.—We performed bolus inhalations of 1-μm particles in four subjects on the ground (1 G) and during parabolic flights both in microgravity (μG) and in ,1.6 G. Boluses of ,70 ml were inhaled at different points in an inspiration from residual volume to 1 liter above functional residual capacity. The volume of air inhaled after the bolus [the penetration volume (Vp)] ranged from 200 to 1,500 ml. Aerosol concentration and flow rate were continuously measured at the mouth. The deposition, dispersion, and position of the bolus in the expired gas were calculated from these data. For Vp $400 ml, both deposition and dispersion increased with Vp and were strongly gravity dependent, with the greatest deposition and dispersion occurring for the largest G level. At Vp 5 800 ml, deposition and dispersion increased from 33.9% and 319 ml in μG to 56.9% and 573 ml at ,1.6 G, respectively (P , 0.05). At each G level, the bolus was expired at a smaller volume than Vp, and this volume became smaller with increasing Vp. Although dispersion was lower in μG than in 1 G and ,1.6 G, it still increased steadily with increasing Vp, showing that nongravitational ventilatory inhomogeneity is partly responsible for dispersion in the human lung.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dispersion and Deposition of Micro Particles over Two Square Obstacles in a Channel via Hybrid Lattice Boltzmann Method and Discrete Phase model

Dispersion and deposition of aerosol particles over two square cylinders confined in a channel in laminar unsteady vortical flow were investigated numerically. Lattice Boltzmann method was used to calculate fluid characteristics and modify Euler method was employed as Lagrangian particle tracing procedure to obtain particle trajectories. Drag, Saffman lift, gravity, buoyancy and Brownian motion...

متن کامل

Effect of gravity on aerosol dispersion and deposition in the human lung after periods of breath holding.

To determine the extent of the role that gravity plays in dispersion and deposition during breath holds, we performed aerosol bolus inhalations of 1-microm-diameter particles followed by breath holds of various lengths on four subjects on the ground (1G) and during short periods of microgravity (microG). Boluses of approximately 70 ml were inhaled to penetration volumes (V(p)) of 150 and 500 ml...

متن کامل

Reduced Gravity and Aerosol Deposition in the Human Lung

provides an overview of those studies as a basis for the consideration of aerosol deposition in the reduced gravity of Mars. Overall deposition: We first performed total deposition studies of 0.5-3 μm-diameter particles in normal gravity (1G), microgravity (μG) and hypergravity (~1.6G) using the NASA Microgravity Research Aircraft [2]. Subjects continuously breathed aerosol from a reservoir at ...

متن کامل

Aerosol bolus dispersion in acinar airways--influence of gravity and airway asymmetry.

The aerosol bolus technique can be used to estimate the degree of convective mixing in the lung; however, contributions of different lung compartments to measured dispersion cannot be differentiated unambiguously. To estimate dispersion in the distal lung, we studied the effect of gravity and airway asymmetry on the dispersion of 1 μm-diameter particle boluses in three-dimensional computational...

متن کامل

Regional deposition and retention of particles in shallow, inhaled boluses: effect of lung volume.

The regional deposition of particles in boluses delivered to shallow lung depths and their subsequent retention in the airways may depend on the lung volume at which the boluses are delivered. To evaluate the effect of end-inspiratory lung volume on aerosol bolus delivery, we had healthy subjects inhale radiolabeled, monodisperse aerosol (99mTc-iron oxide, 3.5-microm mass median aerodynamic dia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998