The Immediate Post-Operative Radiograph is an Unreliable Measure of Coronal Plane Alignment in Total Knee Replacement
نویسندگان
چکیده
BACKGROUND Restoration of a neutral mechanical axis is a primary goal of total knee replacement (TKR). A mechanical axis within 3° of neutral has been correlated with improved implant longevity, function, and patient satisfaction. We hypothesize that the immediate post-operative radiograph is an unreliable method of measuring alignment following TKR surgery. METHODS Seventy-five consecutive patients had supine X-rays performed on day two post-operatively followed by standing long-leg radiographs (LLRs) 6 weeks post-operatively. Correlation was sought between the mechanical axis measured on the LLR and surrogate markers of alignment on the post-operative X-ray including component alignment and an estimation of anatomical alignment using the available length of femoral and tibial shafts. Inter- and intra-observer reliabilities were assessed. RESULTS The mean mechanical axis on the LLR was 180.5 (SD 3.0, range 175.1-187.1). Mean offset between anatomical axis and mechanical axis was 6.4°. The mean anatomical axis measured on the short-leg X-ray was 174.9 (SD 2.4, range 169.5-181.3). Mechanical axis on the LLR was compared to the anatomical axis measured on the short-leg radiograph (SLR) + 6° with an interclass correlation coefficient of 0.588 (p < 0.001). The level of disagreement between the short- and long-leg X-rays was assessed using the Bland-Altman method and demonstrated clinically important discrepancies of 5 or more degrees in 9% of cases. Inter- and intra-observer agreements were high on all measures (p < 0.001). CONCLUSION The long-leg weight bearing X-ray is an essential tool to accurately assess coronal plane alignment post TKR. While the immediate post-operative X-ray taken supine provides useful information to the surgeon on any immediate complications, our results indicate that it cannot be relied upon to determine correct restoration of the mechanical axis.
منابع مشابه
An analysis of intra-operative variation in femorotibial alignment in the coronal plane during computer navigated total knee replacement.
A prospective study was performed to assess the intra-operative variation in femoral and tibial axis alignment during navigated total knee replacement. The intra-operative initial, trial and final mechanical axis alignments were recorded from the navigation system. The mean variation and correlation coefficient were calculated and analysed. There were 40 patients (24 females, 16 males), with ag...
متن کاملCollateral soft tissue release in primary total knee replacement
The aim of this study was to assess the rate of collateral soft tissue release required in navigated total knee arthroplasty (TKA) to achieve an intra-operative coronal femoral tibial mechanical axis (FTMA) in extension of 0 ± 2°. The primary outcomes assessed were post-operative coronal plane alignment and rate of collateral soft tissue release. The secondary outcomes were range of motion, fun...
متن کاملReliability of the hip-to-ankle radiograph in determining the knee and implant alignment after total knee arthroplasty.
Hip-to-ankle radiographs have been used to evaluate lower limb alignment before and after total knee arthroplasty. However, earlier studies have inappropriately used correlation to assess the reproducibility of the radiographs. We determined the reliability of the hip-to-ankle radiograph using the Bland-Altman analysis. Two consecutive hip-to-ankle radiographs were obtained in 52 patients (52 k...
متن کاملA computer-assisted, tibia-first technique for improved femoral component rotation in total knee arthroplasty
Background The use of navigation for total knee arthroplasty (TKA) improves limb alignment in the coronal and sagittal planes. However, similar improvements in femoral and tibial component rotation have not yet been realized using currently available systems. Methods We developed a modified navigated TKA technique in which femoral rotation was set using the resected tibial plane as the refere...
متن کاملThe effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years.
Correct positioning and alignment of components during primary total knee replacement (TKR) is widely accepted to be an important predictor of patient satisfaction and implant durability. This retrospective study reports the effect of the post-operative mechanical axis of the lower limb in the coronal plane on implant survival following primary TKR. A total of 501 TKRs in 396 patients were divi...