Noise and light exposures for extremely low birth weight newborns during their stay in the neonatal intensive care unit.

نویسندگان

  • Robert E Lasky
  • Amber L Williams
چکیده

OBJECTIVES The objectives of this study were to characterize noise and light levels for extremely low birth weight newborns throughout their stay in the NICU, evaluate factors influencing noise and light levels, and determine whether exposures meet recommendations from the American Academy of Pediatrics. METHODS Sound and light were measured inside the beds of extremely low birth weight newborns (n = 22) from birth to discharge. Measurements were recorded for 20 consecutive hours weekly from birth until 36 weeks' postmenstrual age, biweekly until 40 weeks, and every 4 weeks thereafter. Clinical variables including bed type and method of respiratory support were recorded at each session. RESULTS Age-related changes in respiratory support and bed type explained the weekly increase of 0.22 dB in sound level and 3.67 lux in light level. Old incubators were the noisiest bed types, and new incubators were the quietest. Light levels were significantly higher in open beds than in incubators. The variations in noise and light levels over time were greatest for open beds. Noise and light levels were much less affected by respiratory support in incubators compared with open beds. A typical extremely low birth weight neonate was exposed to noise levels averaging 56.44 dB(A) and light levels averaging 70.56 lux during their stay from 26 to 42 weeks' postmenstrual age in the NICU. Noise levels were rarely within American Academy of Pediatrics recommendations (5.51% of the time), whereas light levels almost always met recommendations (99.37% of the time). CONCLUSIONS Bed type and respiratory support explained differences in noise and light levels that extremely low birth weight newborns experience during their hospital stay. Noise levels exceeded recommendations, although evidence supporting those recommendations is lacking. Well-designed intervention studies are needed to determine the effects of noise reduction on the development of extremely low birth weight newborns.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison Study of Causes and Neonatal Mortality Rates of Newborns Admitted in Neonatal Intensive Care Unit of Al-Sadder Teaching Hospital in Al-Amara City, Iraq

BackgroundEach year about 32.4 million of children are born with low birth weight, which is below the 10th percentile for their gestational ages; moreover, about fifteen million of them are premature. Actually, about 60% of neonatal deaths occur in low birth weight neonates related to their prematurity. This study aimed to determine the neonatal death rate and the most common causes of the hosp...

متن کامل

The effect of Yakson touch on neonatal weight of premature infants admitted to the intensive care unit of Taleghani Hospital in Gonbad Kavous 2020

.1 Semnani N, Hojjati H, Akhoundzadeh G. The Effect of Yakson Touch on Pain Control Due to Nasogastric Intubation in Premature Infants Admitted to the Neonatal Intensive Care Unit of Taleghani Gonbad Hospital in 2019. arumshcj. 2020;22(2):93-101. .2 Hanieh Sajadi GAHH. The Effect of Empowerment Program on Participation of Mothers with Premature Infants Hospitalized in Neonatal Intensive Care U...

متن کامل

Effect of mother's infant massage on neonatal weight and perceived self-efficacy of mothers with low birth weight infants

Introduction: Weight is the most important growth factor in newborns and perceived self-efficacy is known as an effective factor weigh gaining. The aim of this study was to determine the effect of mother's infant massage on neonatal weight and perceived self-efficacy of mothers with low birth weight infants. Materials and Methods: 80 infants were divided into intervention and control groups in ...

متن کامل

The Prevalence and Risk Factors for Neonatal Thrombocytopenia among Newborns Admitted to Intensive Care Unit of Aliasghar Children’s Hospital

Background: Determining the prevalence and risk factors of thrombocytopenia among neonates enables us to prevent the inevitable and sometimes irreversible complications. In this study we aimed to survey the frequency of thrombocytopenia and its demographic features and risk factors. Materials and methods: In this cross sectional study the platelet counts of 364 neonates admitted to neonatal ...

متن کامل

Frequency and Risk Factors of Retinopathy of Prematurity in Newborns Admitted to Neonatal Intensive Care Unit in Hamadan

Background and Objective: Retinopathy of prematurity (ROP) is an evolutionary disorder in the retina of premature infants. Nowadays, the prevalence rate of retinopathy has increased due to the advancement of medical facilities and the increased survival of preterm infants. The aim of this study was to determine the prevalence rate of ROP and its related risk factors among infants admitted to an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatrics

دوره 123 2  شماره 

صفحات  -

تاریخ انتشار 2009