Quantitative analysis of NK1 receptor in the human brain using PET with 18F-FE-SPA-RQ.

نویسندگان

  • Masaki Okumura
  • Ryosuke Arakawa
  • Hiroshi Ito
  • Chie Seki
  • Hidehiko Takahashi
  • Harumasa Takano
  • Eisuke Haneda
  • Ryuji Nakao
  • Hidenori Suzuki
  • Kazutoshi Suzuki
  • Yoshiro Okubo
  • Tetsuya Suhara
چکیده

UNLABELLED 18F-fluoroethyl-SPA-RQ (18F-FE-SPA-RQ) was recently developed as a radioligand for the measurement of neurokinin 1 (NK1) receptor with PET. In this study, we used 18F-FE-SPA-RQ with PET to visualize and quantify NK1 receptor in the human brain. METHODS PET scans were performed on 7 healthy men after intravenous injection of 18F-FE-SPA-RQ. Binding potential (BPND) was calculated by the indirect kinetic, simplified reference tissue model (SRTM), and ratio methods. The indirect kinetic method was used as the gold standard method and was compared with the SRTM method, with scan times of 180, 270, and 330 min, and with the ratio method, with time integration intervals of 120-180, 210-270, and 300-330 min. The cerebellum was used as the reference brain region. RESULTS Regional radioactivity was highest in the caudate head and putamen; mid level in the parahippocampus, cerebral cortex, and thalamus; and lowest in the cerebellum. BPND values by the indirect kinetic method were 3.15 +/- 0.36, 3.11 +/- 0.66, 1.17 +/- 0.25, and 0.46 +/- 0.14 in the caudate, putamen, parahippocampal region, and thalamus, respectively. For cerebral cortical regions, BPND values by the indirect kinetic method were 0.94 +/- 0.23, 0.82 +/- 0.15, 0.76 +/- 0.15, and 0.69 +/- 0.16 in the occipital, temporal, frontal, and anterior cingulate cortices, respectively. BPND values by the SRTM and ratio methods were in good agreement with those by the indirect kinetic method (r = 0.94-0.98). CONCLUSION The regional distribution of 18F-FE-SPA-RQ was in agreement with previous PET studies and postmortem studies of NK1 receptor in the human brain. The ratio method will be useful for clinical research of psychiatric disorders, for the estimation of NK1 receptor without arterial blood sampling and long dynamic PET.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gender and age affect NK1 receptors in the human brain - a positron emission tomography study with [18F]SPA-RQ.

Substance P (SP) is a neurotransmitter and neuromodulator that mediates its effects in the brain predominantly via the neurokinin-1 receptors (NK1Rs). NK1Rs and SP have been shown clinically to be involved in nausea and emesis after chemotherapy (CINV) and have been implicated preclinically in a range of neuropsychiatric disorders but unlike CINV their blockade in these conditions does not have...

متن کامل

The effect of incorporating the quantitative analysis besides visual assessments of 18F-FDG brain PET images for the localization of epileptogenic zones

Introduction: FDG Brain PET is a valuable paraclinical tool for presurgical assessments of patients suffering from refractory epilepsy. By the widespread accessibility of PET, recognizing the functional lesions has become a current practical method especially in preoperative evaluations of the partial epilepsy disorders. The aim of our study was to assess the impact of quantit...

متن کامل

Diagnosis of Brain Tumors Using Amino Acid Transport PET Imaging With 18F- Fluciclovine: A Comparison Study With L-Methyl-11C-Methionine PET Imaging

Objective(s): 18F-fluciclovine (trans-1-amino-3-[18F] fluorocyclobutanecarboxylic acid, [FACBC]) is an artificial amino acid radiotracer used for positron emission tomography (PET) studies, which is metabolically stable in vivo and has a long half-life. It has already been shown that FACBC-PET is useful for glioma imaging. However, there have been no reports evaluating the efficiency of FACBC-P...

متن کامل

Diagnostic Performance and Safety of Positron Emission Tomography Using 18F-Fluciclovine in Patients with Clinically Suspected High- or Low-grade Gliomas: A Multicenter Phase IIb Trial

Objective(s): The study objective was to assess the diagnostic performance of positron emission tomography (PET) for gliomas using the novel tracer 18F-fluciclovine (anti-[18F]FACBC) and to evaluate the safety of this tracer in patients with clinically suspected gliomas.Methods: Anti-[18F]FACBC was administered to 40 patients with clinically suspected high- or low-grade gliomas, followed by PET...

متن کامل

Quantification of Central Substance P Receptor Occupancy by Aprepitant Using Small Animal Positron Emission Tomography

BACKGROUND Central substance P receptors, termed NK-1 receptors, have been considered as therapeutic targets in the development of drugs against diverse conditions, including emesis, overactive bladder, and depression. METHODS Here, we applied small animal positron emission tomography (PET) and a radioligand for NK-1 receptors ([(18)F]FE-SPA-RQ) for measuring occupancies of these receptors by...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 49 11  شماره 

صفحات  -

تاریخ انتشار 2008