Rapid determination of bacteriological water quality by using limulus lysate.

نویسندگان

  • T M Evans
  • J E Schillinger
  • D G Stuart
چکیده

The Limulus lysate assay was used to measure the endotoxin content in stream water and was found to reflect the degree of bacterial contamination as measured by coliform, enteric, gram-negative, and heterotrophic bacteria. The firm-clot method was found to be a less sensitive and reproducible technique for the detection of endotoxin than was the spectrophotometric modification of the Limulus lysate assay. Bound endotoxin, as determined by the spectrophotometric modification of the Limulus lysate assay, was found to be a better measure of the endotoxin associated with bacterial cells than was total endotoxin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test

The possibility of replacing the rabbit pyrogen test by the Limulus Amebocyte lysate (LAL) test, as a final release test for Large Volume Parenterals (LVPs) was investigated. The sensitivity and specificity of the LAL test and rabbit pyrogen assay were studied by means of artificially contaminated parenterals. Various LVPs (mostly containing electrolytes) were spiked with 0.5 and 5 EUlml o...

متن کامل

Bacteriological monitoring of dialysis fluid in 2 hemodialysis units in Alexandria, Egypt.

OBJECTIVE To assess the bacteriological quality of dialysis fluid in 2 hemodialysis units in Alexandria, Egypt. METHODS A total of 321 samples of hemodialysis fluids, 213 from unit A (a governmental unit), 108 from unit B (a private unit), both under the supervision of ministry of health, were collected from the water treatment system (WTS), treated water, concentrates, and final dialysate fr...

متن کامل

Adaptation of a microdilution procedure to the Limulus lysate assay for endotoxin.

Endpoint determinations of endotoxin by the Limulus amoebocyte lysate assay have been facilitated by use of a microdilution procedure.

متن کامل

Chromogenic Limulus amoebocyte lysate assay for rapid detection of gram-negative bacteriuria.

A chromogenic Limulus amoebocyte lysate assay was evaluated as a rapid screening test for the detection of clinically significant gram-negative bacteriuria. The development of a distinctive yellow color after the addition of chromogenic substrate to the Limulus amoebocyte lysate-urine reaction mixture was used to measure greater than or equal to 10(5) gram-negative bacteria per ml. A total of 3...

متن کامل

Microbiological assessment of house and imported bottled water by comparison of bacterial endotoxin concentration, heterotrophic plate count, and fecal coliform count.

Consumers increasingly use bottled water and home water treatment systems to avoid direct tap water. According to the International Bottled Water Association (IBWA), an industry trade group, 5 billion gallons of bottled water were consumed by North Americans in 2001. The principal aim of this study was to assess the microbial quality of in-house and imported bottled water for human consumption,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 1978